Evidence map›Paper›PMID 38835568›Full record

ArticleJTCVS techniques2024

Hybrid stage 1 palliation with simultaneous off-pump ventricular assist device placement in neonates with high-risk single ventricle anatomy: Initial experience.

Constantine D Mavroudis, Matthew J O'Connor, Carol Wittlieb-Weber, Jonathan B Edelson, Jonathan J Edwards, Justin H Berger, Kimberly Y Lin, Joseph Rossano, Katsuhide Maeda

Abstract read
In one paragraph

Article in JTCVS techniques, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Constantine D MavroudisDivisions of Cardiothoracic Surgery and Cardiology, Children's Hospital of Philadelphia, Philadelphia, Pa.
Matthew J O'ConnorDivisions of Cardiothoracic Surgery and Cardiology, Children's Hospital of Philadelphia, Philadelphia, Pa.
Carol Wittlieb-WeberDivisions of Cardiothoracic Surgery and Cardiology, Children's Hospital of Philadelphia, Philadelphia, Pa.
Jonathan B EdelsonDivisions of Cardiothoracic Surgery and Cardiology, Children's Hospital of Philadelphia, Philadelphia, Pa.
Jonathan J EdwardsDivisions of Cardiothoracic Surgery and Cardiology, Children's Hospital of Philadelphia, Philadelphia, Pa.
Justin H BergerDivisions of Cardiothoracic Surgery and Cardiology, Children's Hospital of Philadelphia, Philadelphia, Pa.
Kimberly Y LinDivisions of Cardiothoracic Surgery and Cardiology, Children's Hospital of Philadelphia, Philadelphia, Pa.
Joseph RossanoDivisions of Cardiothoracic Surgery and Cardiology, Children's Hospital of Philadelphia, Philadelphia, Pa.
Katsuhide MaedaDivisions of Cardiothoracic Surgery and Cardiology, Children's Hospital of Philadelphia, Philadelphia, Pa.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Infants with single ventricle heart disease and severe atrioventricular valve regurgitation have poor outcomes following conventional staged palliation. As such, ventricular assist device (VAD) placement along with hybrid stage 1 palliation has been proposed as a bridge to heart transplant. We present a novel surgical technique for VAD implantation concurrent with hybrid stage 1 that avoids cardiopulmonary bypass. Methods: We performed a retrospective review of our institutional experience with this novel surgical technique. Results: Three patients (weight, 2.7-3.5 kg; age, 3 to 5 days) underwent hybrid stage 1 with VAD placement, consisting of bilateral 3.5-mm expandable polytetrafluoroethylene (PTFE) pulmonary artery bands, a ductal stent, a 6-mm Berlin Heart outflow cannula onto the main pulmonary trunk with a 10-mm graft, a 6-mm Berlin Heart outflow cannula onto the right atrium, and a 10-mL Berlin Heart pump. In patients with severe aortic arch hypoplasia or coarctation, a 4-mm PTFE graft was sewn from the VAD outflow graft to the innominate artery to protect coronary and cerebral perfusion. Procedures were performed off bypass with minimal blood product use. Patients were extubated on postoperative days 2, 2, and 5. There were no procedural complications. All patients were transferred out of the intensive care unit and demonstrated appropriate weight gain. Anticoagulation strategy was bivalirudin and antiplatelet therapy. The patients underwent transplantation after 149 days, 157 days, and 288 days of support. Conclusions: Off-pump single ventricle VAD placement is technically feasible and can be done at the time of hybrid stage 1 palliation with minimal operative morbidity as a bridge to transplant.

Indexed as

bridge to transplantcongenital heart diseaseheart failurehybrid proceduresingle ventricle heart diseasestaged palliationventricular assist device

Identifiers

PMID38835568
PMCPMC11145030

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.