Evidence map›Paper›PMID 38833204›Full record

ArticleJournal of robotic surgery2024

Patient-specific placental vessel segmentation with limited data.

Gary Sarwin, Jonas Lussi, Simone Gervasoni, Ueli Moehrlen, Nicole Ochsenbein, Bradley J Nelson

Abstract read
In one paragraph

Article in Journal of robotic surgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Gary SarwinComputer Vision Lab, ETH Zurich, 8092, Zurich, Switzerland. gary.sarwin@vision.ee.ethz.ch.
Jonas LussiMulti-Scale Robotics Lab, ETH Zurich, 8092, Zurich, Switzerland.
Simone GervasoniMulti-Scale Robotics Lab, ETH Zurich, 8092, Zurich, Switzerland.
Ueli MoehrlenDepartment of Pediatric Surgery, University Children's Hospital Zurich, 8032, Zurich, Switzerland.
Nicole OchsenbeinDepartment of Obstetrics, University Hospital of Zurich, 8091, Zurich, Switzerland.
Bradley J NelsonMulti-Scale Robotics Lab, ETH Zurich, 8092, Zurich, Switzerland.

Funding

European Research Council 743217Horizon 2020 Framework Programme 952152Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung 200020B_185039
6 · The paper itself

Abstract

A major obstacle in applying machine learning for medical fields is the disparity between the data distribution of the training images and the data encountered in clinics. This phenomenon can be explained by inconsistent acquisition techniques and large variations across the patient spectrum. The result is poor translation of the trained models to the clinic, which limits their implementation in medical practice. Patient-specific trained networks could provide a potential solution. Although patient-specific approaches are usually infeasible because of the expenses associated with on-the-fly labeling, the use of generative adversarial networks enables this approach. This study proposes a patient-specific approach based on generative adversarial networks. In the presented training pipeline, the user trains a patient-specific segmentation network with extremely limited data which is supplemented with artificial samples generated by generative adversarial models. This approach is demonstrated in endoscopic video data captured during fetoscopic laser coagulation, a procedure used for treating twin-to-twin transfusion syndrome by ablating the placental blood vessels. Compared to a standard deep learning segmentation approach, the pipeline was able to achieve an intersection over union score of 0.60 using only 20 annotated images compared to 100 images using a standard approach. Furthermore, training with 20 annotated images without the use of the pipeline achieves an intersection over union score of 0.30, which, therefore, corresponds to a 100% increase in performance when incorporating the pipeline. A pipeline using GANs was used to generate artificial data which supplements the real data, this allows patient-specific training of a segmentation network. We show that artificial images generated using GANs significantly improve performance in vessel segmentation and that training patient-specific models can be a viable solution to bring automated vessel segmentation to the clinic.

Indexed as

PlacentaDeep LearningFemaleFetofetal TransfusionHumansImage Processing, Computer-AssistedMachine LearningNeural Networks, ComputerPregnancyRobotic Surgical ProceduresGenerative adversarial networksMedical image generationSegmentationTwin-to-twin transfusion syndrome

Identifiers

PMID38833204
PMCPMC11150325

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.