ArticleDrug delivery and translational research2025
3D printed needleless injector based on thermocavitation: analysis of impact and penetration depth in skin phantoms in a repetitive regime.
Article in Drug delivery and translational research, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
A global issue that requires attention is the duality between the shortage of needles for regular vaccination campaigns and the exponential increase in syringe and needle waste from such campaigns, which has been exacerbated by the COVID-19 pandemic. In response to this problem, this study presents a 3D printed needleless injector based on thermocavitation. The work focused on investigating the interaction of the resulting liquid jets with skin phantoms at different concentrations (1-2%), emphasizing their impact and penetration depth in a repetitive regime. The injector was designed and fabricated from a semi-transparent polymer using a high-resolution 3D printer, allowing the ejection of liquid jets with velocities up to ~ 73 m/s. The impact of these jets on skin phantoms was evaluated using a high-speed camera. After 6 consecutive liquid jets (1% concentration), a maximum penetration depth of ~ 2.5 mm was achieved, delivering approximately 4.7 µL. For the highest concentration (2.0%) and the same number of shots, the penetration depth was reduced to ~ 0.6 mm with a delivered volume of ~ 0.7 µL. An important finding of this study is that the liquid jet with the highest pressure does not cause the maximum penetration depth, but is the result of a series of successive shots. In addition, the velocity and shape of the ejected jet are determined by the amount of solution and the meniscus formed inside the injector. These findings advance the development of precise and efficient thermocavitation-based injectors with broad potential applications in medical and pharmaceutical fields.
Indexed as
Identifiers
38831200What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.