ArticleJournal of imaging informatics in medicine2024
CSAMDT: Conditional Self Attention Memory-Driven Transformers for Radiology Report Generation from Chest X-Ray.
Article in Journal of imaging informatics in medicine, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- From Detection to Radiology Report Generation: Fine-Grained Multi-Modal Alignment with Semi-Supervised Learning.Journal of imaging informatics in medicine · 2026Article
- ChestX-Transcribe: a multimodal transformer for automated radiology report generation from chest x-rays.Frontiers in digital health · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
Abstract
A radiology report plays a crucial role in guiding patient treatment, but writing these reports is a time-consuming task that demands a radiologist's expertise. In response to this challenge, researchers in the subfields of artificial intelligence for healthcare have explored techniques for automatically interpreting radiographic images and generating free-text reports, while much of the research on medical report creation has focused on image captioning methods without adequately addressing particular report aspects. This study introduces a Conditional Self Attention Memory-Driven Transformer model for generating radiological reports. The model operates in two phases: initially, a multi-label classification model, utilizing ResNet152 v2 as an encoder, is employed for feature extraction and multiple disease diagnosis. In the second phase, the Conditional Self Attention Memory-Driven Transformer serves as a decoder, utilizing self-attention memory-driven transformers to generate text reports. Comprehensive experimentation was conducted to compare existing and proposed techniques based on Bilingual Evaluation Understudy (BLEU) scores ranging from 1 to 4. The model outperforms the other state-of-the-art techniques by increasing the BLEU 1 (0.475), BLEU 2 (0.358), BLEU 3 (0.229), and BLEU 4 (0.165) respectively. This study's findings can alleviate radiologists' workloads and enhance clinical workflows by introducing an autonomous radiological report generation system.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.