Evidence map›Paper›PMID 38831168›Full record

ArticleJournal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing2024

In vivo safety and pulmonary vein isolation performance of a new cryoballoon for the treatment of atrial fibrillation.

Rong Bai, Yu Liao, Xunzhang Wang, Kevin Rosenthal, Justin Vessey, Meital Mazor, Wilber Su

Abstract read
PubMed Publisher
In one paragraph

Article in Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Rong BaiDivision of Cardiology, Banner-University Medicine Heart Institute, Banner University Medical Center-Phoenix, College of Medicine, University of Arizona, 755. E McDowell Road, Floor 4, Phoenix, 85006, AZ, USA. bairong74@gmail.com.ORCID http://orcid.org/0000-0002-3106-7318
Yu LiaoDepartment of Internal Medicine, Division of Cardiology, National Cheng Kung University Hospital, Tainan, Taiwan.
Xunzhang WangDepartment of Cardiology, Smidt Heart Institute, Cedars-Sinai, Los Angeles, CA, USA.
Kevin RosenthalSynaptic Medical, Carlsbad, CA, USA.
Justin VesseySynaptic Medical, Carlsbad, CA, USA.
Meital MazorSynaptic Medical, Carlsbad, CA, USA.
Wilber SuDivision of Cardiology, Banner-University Medicine Heart Institute, Banner University Medical Center-Phoenix, College of Medicine, University of Arizona, 755. E McDowell Road, Floor 4, Phoenix, 85006, AZ, USA. wilwsu@gmail.com.ORCID http://orcid.org/0000-0002-0639-6822

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundCryoablation to achieve pulmonary vein (PV) isolation has become one of the standard approaches for atrial fibrillation (AF) ablation. The Arctic Front series cryoballoon and Achieve circular mapping catheter (Medtronic) inherently possess design defects that have been associated with unfavorite clinical outcomes. Lately, a new cryoablation system (Nordica Cryoablation System, Synaptic Medical) was developed with improved design of the cryoballoon and circular mapping catheter to address the inadequacies of current cryoablation technology. An animal study was conducted to test the efficacy and safety in performing PVI with the Nordica Cryoablation System.

methodsPulmonary vein isolation with the Nordica Cryoablation System was performed on 12 PVs of six healthy canines. Acute PVI and peri-procedural complications were recorded. All animals underwent a repeat EP study at least 4 weeks after index procedures followed by pathological and histological assessments of the heart and collateral/downstream organs after planned euthanasia.

resultsAcute PV isolation was achieved in all targeted PVs with 50% of PVs being isolated with a single cryoablation application. There were no major peri-procedural complications or device malfunction events. All PVs remained isolated after 29-30 days follow-up. Histological examination showed transmural cryo-lesions at treated sites with minimal inflammation, neovascularization, and neointima formation but no significant injury to adjacent tissue or embolization in downstream organs.

conclusionAcute and durable PVI can be achieved by using the novel Nordica Cryoablation System. Ablation with this new cryoablation system is associated with transmural lesions at targeted myocardium but creates no injury to the collateral tissues or downstream organs.

Indexed as

Atrial FibrillationCryosurgeryPulmonary VeinsAnimalsDisease Models, AnimalDogsEquipment DesignTreatment OutcomeAtrial fibrillationCryoablationCryoballoonPulmonary vein isolation

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked