ArticlePediatric cardiology2025
Suboptimal Imaging on Obstetric Ultrasound Should Prompt Early Referral for Fetal Echocardiography.
Article in Pediatric cardiology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Current status and prospects of prenatal ultrasound diagnosis of congenital heart disease in fetuses: a narrative review.Translational pediatrics · 2026Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Recent studies suggest that suboptimal cardiac imaging on routine obstetric anatomy ultrasound (OB-scan) is not associated with a higher risk for congenital heart disease (CHD) and, therefore, should not be an indication for fetal echocardiography (F-echo). We aim to determine the incidence of CHD in patients referred for suboptimal imaging in a large catchment area, including regions that are geographically distant from a tertiary care center. We conducted a retrospective chart review of patients referred to Seattle Children's Hospital (SCH) and SCH Regional Cardiology sites (SCH-RC) from 2011 to 2021 for F-echo with the indication of suboptimal cardiac imaging by OB-scan. Of 454 patients referred for suboptimal imaging, 21 (5%) of patients were diagnosed with CHD confirmed on postnatal echo. 10 patients (2%) required intervention by age one. Mean GA at F-echo was significantly later for suboptimal imaging compared to all other referral indications (27.5 ± 3.9 vs 25.2 ± 5.2 weeks, p < 0.01). Mean GA at F-echo was also significantly later at SCH-RC compared to SCH (29.2 ± 4.6 vs 24.2 ± 2.9 weeks; p < 0.01). In our experience, CHD in patients referred for suboptimal imaging is higher (5%) than previously described, suggesting that routine referral for is warranted. Furthermore, while suboptimal imaging was associated with a delayed F-echo compared to other indications, this delay was most striking for those seen at regional sites. This demonstrates a potential disparity for these patients and highlights opportunities for targeted education in cardiac assessment for primary providers in these regions.
Indexed as
Identifiers
38831151What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.