Evidence map›Paper›PMID 38831151›Full record

ArticlePediatric cardiology2025

Suboptimal Imaging on Obstetric Ultrasound Should Prompt Early Referral for Fetal Echocardiography.

Hailey N Chambers, Elizabeth Caris, Jeffrey Conwell, Lindsay A Edwards, J Eddie Hulse, Mark Lewin, Nelangi M Pinto, Elana Wolfe, Bhawna Arya

Abstract read
PubMed Publisher
In one paragraph

Article in Pediatric cardiology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Hailey N ChambersSeattle Children's Hospital, University of Washington Medical Center, OC.7.830, 4800 Sandpoint Way NE, Seattle, WA, 98105, USA. hailey.chambers@seattlechildrens.org.
Elizabeth CarisUPMC Children's Hospital of Pittsburgh, Pittsburgh, PA, USA.
Jeffrey ConwellSeattle Children's Hospital, University of Washington Medical Center, Seattle, WA, USA.
Lindsay A EdwardsDuke University Medical Center, Durham, NC, USA.
J Eddie HulseSeattle Children's Hospital, University of Washington Medical Center, Seattle, WA, USA.
Mark LewinSeattle Children's Hospital, University of Washington Medical Center, Seattle, WA, USA.
Nelangi M PintoSeattle Children's Hospital, University of Washington Medical Center, Seattle, WA, USA.
Elana WolfeSeattle Children's Hospital, University of Washington Medical Center, Seattle, WA, USA.
Bhawna AryaSeattle Children's Hospital, University of Washington Medical Center, Seattle, WA, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Recent studies suggest that suboptimal cardiac imaging on routine obstetric anatomy ultrasound (OB-scan) is not associated with a higher risk for congenital heart disease (CHD) and, therefore, should not be an indication for fetal echocardiography (F-echo). We aim to determine the incidence of CHD in patients referred for suboptimal imaging in a large catchment area, including regions that are geographically distant from a tertiary care center. We conducted a retrospective chart review of patients referred to Seattle Children's Hospital (SCH) and SCH Regional Cardiology sites (SCH-RC) from 2011 to 2021 for F-echo with the indication of suboptimal cardiac imaging by OB-scan. Of 454 patients referred for suboptimal imaging, 21 (5%) of patients were diagnosed with CHD confirmed on postnatal echo. 10 patients (2%) required intervention by age one. Mean GA at F-echo was significantly later for suboptimal imaging compared to all other referral indications (27.5 ± 3.9 vs 25.2 ± 5.2 weeks, p < 0.01). Mean GA at F-echo was also significantly later at SCH-RC compared to SCH (29.2 ± 4.6 vs 24.2 ± 2.9 weeks; p < 0.01). In our experience, CHD in patients referred for suboptimal imaging is higher (5%) than previously described, suggesting that routine referral for is warranted. Furthermore, while suboptimal imaging was associated with a delayed F-echo compared to other indications, this delay was most striking for those seen at regional sites. This demonstrates a potential disparity for these patients and highlights opportunities for targeted education in cardiac assessment for primary providers in these regions.

Indexed as

EchocardiographyFetal HeartHeart Defects, CongenitalReferral and ConsultationUltrasonography, PrenatalFemaleHumansIncidencePregnancyRetrospective StudiesCardiac screeningFetal echoHeart not well visualizedPrenatal diagnosis

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.