Evidence map›Paper›PMID 38829913›Full record

ArticlePloS one2024

Accuracy and feasibility in building a personalized 3D printed femoral pseudoaneurysm model for endovascular training.

Suat Yee Lee, Shen Cheak Currina Chew, Pei Hua Lee, Hung Da Chen, Shao Min Huang, Chun Hung Liu, Fatt Yang Chew

Abstract read
In one paragraph

Article in PloS one, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Suat Yee LeeDepartment of Pathology, Chung Shan Medical University Hospital, Taichung, Taiwan.
Shen Cheak Currina ChewFaculty of Social Sciences & Humanities, University of Technology, Johor Bahru, Malaysia.
Pei Hua LeeDepartment of Medical Imaging, China Medical University Hospital, Taichung, Taiwan.
Hung Da ChenDepartment of Medical Imaging, China Medical University Hospital, Taichung, Taiwan.
Shao Min HuangDepartment of Medicine, Show Chwan Memorial Hospital, Chang Hua, Taiwan.ORCID 0000-0002-7804-2652
Chun Hung LiuDepartment of Medical Imaging, China Medical University Hospital, Taichung, Taiwan.ORCID 0000-0002-7579-9545
Fatt Yang ChewDepartment of Medical Imaging, China Medical University Hospital, Taichung, Taiwan.ORCID 0000-0002-8965-6131

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe use of three-dimensional(3D) printing is broadly across many medical specialties. It is an innovative, and rapidly growing technology to produce custom anatomical models and medical conditions models for medical teaching, surgical planning, and patient education. This study aimed to evaluate the accuracy and feasibility of 3D printing in creating a superficial femoral artery pseudoaneurysm model based on CT scans for endovascular training.

methodsA case of a left superficial femoral artery pseudoaneurysm was selected, and the 3D model was created using DICOM files imported into Materialise Mimics 22.0 and Materialise 3-Matic software, then printed using vat polymerization technology. Two 3D-printed models were created, and a series of comparisons were conducted between the 3D segmented images from CT scans and these two 3D-printed models. Ten comparisons involving internal diameters and angles of the specific anatomical location were measured.

resultsThe study found that the absolute mean difference in diameter between the 3D segmented images and the 3D printed models was 0.179±0.145 mm and 0.216±0.143mm, respectively, with no significant difference between the two sets of models. Additionally, the absolute mean difference in angle was 0.99±0.65° and 1.00±0.91°, respectively, and the absolute mean difference in angle between the two sets of data was not significant. Bland-Altman analysis confirmed a high correlation in dimension measurements between the 3D-printed models and segmented images. Furthermore, the accuracy of a 3D-printed femoral pseudoaneurysm model was further tested through the simulation of a superficial femoral artery pseudoaneurysm coiling procedure using the Philips Azurion7 in the angiography room.

conclusions3D printing is a reliable technique for producing a high accuracy 3D anatomical model that closely resemble a patient's anatomy based on CT images. Additionally, 3D printing is a feasible and viable option for use in endovascular training and medical education. In general, 3D printing is an encouraging technology with diverse possibilities in medicine, including surgical planning, medical education, and medical device advancement.

Indexed as

Aneurysm, FalseEndovascular ProceduresFeasibility StudiesFemoral ArteryModels, AnatomicPrinting, Three-DimensionalTomography, X-Ray ComputedHumansImaging, Three-Dimensional

Identifiers

PMID38829913
PMCPMC11146720

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.