Evidence map›Paper›PMID 38829894›Full record

Trial reportPloS one2024

Description of mitochondrial oxygen tension and its variability in healthy volunteers.

Meryem Baysan, Mark Broere, Maarten E Wille, Jule E Bergsma, Egbert G Mik, Nicole P Juffermans, Roula Tsonaka, Johanna G van der Bom, Sesmu M Arbous

Registry-linked trialAbstract readClinical Trial
In one paragraph

Trial report in PloS one, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT04626661 (Mitochondrial Oxygen Measurement Variability in Critically Ill Patients), which is not on this map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT04626661 completednot on this map

Mitochondrial Oxygen Measurement Variability in Critically Ill Patients: Validation of the COMET Measurement System

TypeobservationalSponsorSanquin-LUMC J.J van Rood Center for Clinical Transfusion ResearchRan2020 to 2023Enrolled33ConditionsMitochondrial Oxygenation Measurement, Measurement Error, HealthyArmsCOMET measurement system
3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Trial
  2. Review
  3. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Meryem BaysanDepartment of Intensive Care Medicine, Leiden University Medical Center, Leiden, the Netherlands.ORCID 0000-0002-8642-4802
Mark BroereDepartment of Intensive Care Medicine, Leiden University Medical Center, Leiden, the Netherlands.ORCID 0009-0002-7756-6996
Maarten E WilleDepartment of Intensive Care Medicine, Leiden University Medical Center, Leiden, the Netherlands.
Jule E BergsmaDepartment of Intensive Care Medicine, Leiden University Medical Center, Leiden, the Netherlands.
Egbert G MikDepartment of Anesthesiology, Laboratory of Experimental Anesthesiology, Erasmus MC- University Medical Center Rotterdam, Rotterdam, the Netherlands.
Nicole P JuffermansDepartment of Intensive Care Medicine, OLVG Hospital, Amsterdam, the Netherlands.
Roula TsonakaDepartment of Biomedical Data Sciences, Leiden University Medical Center, Leiden, the Netherlands.
Johanna G van der BomDepartment of Clinical Epidemiology, Leiden University Medical Center, Leiden, the Netherlands.
Sesmu M ArbousDepartment of Intensive Care Medicine, Leiden University Medical Center, Leiden, the Netherlands.ORCID 0000-0001-5242-3257

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesDescribing mitochondrial oxygenation (mitoPO2) and its within- and between-subject variability over time after 5-aminolevulinic acid (ALA) plaster application in healthy volunteers.

designProspective cohort study.

settingMeasurements were performed in Leiden University Medical Center, the Netherlands.

participantsHealthy volunteers enrolled from July to September 2020.

interventionsTwo ALA plasters were placed parasternal left and right, with a 3-hour time interval, to examine the influence of the calendar time on the value of mitoPO2. We measured mitoPO2 at 4, 5, 7, 10, 28, and 31 hours after ALA plaster 1 application, and at 4, 5, 7, 25, and 28 hours after ALA plaster 2 application. PRIMARY AND SECONDARY OUTCOME MEASURES: At each time point, five mitoPO2 measurements were performed. Within-subject variability was defined as the standard deviation (SD) of the mean of five measurements per timepoint of a study participant. The between-subject variability was the SD of the mean mitoPO2 value of the study population per timepoint.

resultsIn 16 completed inclusions, median mitoPO2 values and within-subject variability were relatively similar over time at all time points for both plasters. An increase in overall between-subject variability was seen after 25 hours ALA plaster time (19.6 mm Hg vs 23.9 mm Hg after respectively 10 and 25 hours ALA plaster time).

conclusionsThe mitoPO2 values and within-subject variability remained relatively stable over time in healthy volunteers. An increase in between-subject variability was seen after 25 hours ALA plaster time warranting replacement of the ALA plaster one day after its application.

trial registrationClinicalTrials.gov with trial number NCT04626661.

Indexed as

Healthy VolunteersOxygenAdultAminolevulinic AcidFemaleHumansMaleMiddle AgedMitochondriaNetherlandsOxygen ConsumptionProspective StudiesYoung AdultAminolevulinic AcidOxygen

Identifiers

PMID38829894
PMCPMC11146699

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.