Pillar data-acquisition strategies for cryo-electron tomography of beam-sensitive biological samples.

James M Parkhurst, Trond Varslot, Maud Dumoux, C Alistair Siebert, Michele Darrow, Mark Basham, Angus Kirkland, Michael Grange, Gwyndaf Evans, James H Naismith

Abstract read
In one paragraph

Article in Acta crystallographica. Section D, Structural biology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Recent advances in correlative cryo-light and electron microscopy.Current opinion in structural biology · 2024
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

James M ParkhurstRosalind Franklin Institute, Harwell Science and Innovation Campus, Didcot OX11 0FA, United Kingdom.
Trond VarslotThermo Fisher Scientific, Vlastimila Pecha, Brno, Czechia.
Maud DumouxRosalind Franklin Institute, Harwell Science and Innovation Campus, Didcot OX11 0FA, United Kingdom.
C Alistair SiebertDiamond Light Source, Harwell Science and Innovation Campus, Didcot OX11 0DE, United Kingdom.
Michele DarrowRosalind Franklin Institute, Harwell Science and Innovation Campus, Didcot OX11 0FA, United Kingdom.
Mark BashamRosalind Franklin Institute, Harwell Science and Innovation Campus, Didcot OX11 0FA, United Kingdom.ORCID 0000-0002-8438-1415
Angus KirklandRosalind Franklin Institute, Harwell Science and Innovation Campus, Didcot OX11 0FA, United Kingdom.
Michael GrangeRosalind Franklin Institute, Harwell Science and Innovation Campus, Didcot OX11 0FA, United Kingdom.
Gwyndaf EvansRosalind Franklin Institute, Harwell Science and Innovation Campus, Didcot OX11 0FA, United Kingdom.ORCID 0000-0002-6079-2201
James H NaismithRosalind Franklin Institute, Harwell Science and Innovation Campus, Didcot OX11 0FA, United Kingdom.ORCID 0000-0001-6744-5061

Funding

Wellcome TrustWellcome Trust 220526/Z/20/Z
6 · The paper itself

Abstract

For cryo-electron tomography (cryo-ET) of beam-sensitive biological specimens, a planar sample geometry is typically used. As the sample is tilted, the effective thickness of the sample along the direction of the electron beam increases and the signal-to-noise ratio concomitantly decreases, limiting the transfer of information at high tilt angles. In addition, the tilt range where data can be collected is limited by a combination of various sample-environment constraints, including the limited space in the objective lens pole piece and the possible use of fixed conductive braids to cool the specimen. Consequently, most tilt series are limited to a maximum of ±70°, leading to the presence of a missing wedge in Fourier space. The acquisition of cryo-ET data without a missing wedge, for example using a cylindrical sample geometry, is hence attractive for volumetric analysis of low-symmetry structures such as organelles or vesicles, lysis events, pore formation or filaments for which the missing information cannot be compensated by averaging techniques. Irrespective of the geometry, electron-beam damage to the specimen is an issue and the first images acquired will transfer more high-resolution information than those acquired last. There is also an inherent trade-off between higher sampling in Fourier space and avoiding beam damage to the sample. Finally, the necessity of using a sufficient electron fluence to align the tilt images means that this fluence needs to be fractionated across a small number of images; therefore, the order of data acquisition is also a factor to consider. Here, an n-helix tilt scheme is described and simulated which uses overlapping and interleaved tilt series to maximize the use of a pillar geometry, allowing the entire pillar volume to be reconstructed as a single unit. Three related tilt schemes are also evaluated that extend the continuous and classic dose-symmetric tilt schemes for cryo-ET to pillar samples to enable the collection of isotropic information across all spatial frequencies. A fourfold dose-symmetric scheme is proposed which provides a practical compromise between uniform information transfer and complexity of data acquisition.

Indexed as

Cryoelectron MicroscopyElectron Microscope TomographyFourier AnalysisImage Processing, Computer-AssistedSignal-To-Noise Ratioalignmentbeam-sensitive specimenscryo-electron tomographycryo-ETdata-collection strategymultislice image simulationreconstruction

Identifiers

PMID38829361
PMCPMC11154591

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.