A Practical Method for Slice Spacing Measurement Using the American Association of Physicists in Medicine Computed Tomography Performance Phantom.

Choirul Anam, Ariij Naufal, Yanurita Dwihapsari, Toshioh Fujibuchi, Geoff Dougherty

Abstract read
In one paragraph

Article in Journal of medical physics. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Choirul AnamDepartment of Physics, Faculty of Sciences and Mathematics, Diponegoro University, Tembalang, Semarang, Central Java, Surabaya, East Java, Indonesia.
Ariij NaufalDepartment of Physics, Faculty of Sciences and Mathematics, Diponegoro University, Tembalang, Semarang, Central Java, Surabaya, East Java, Indonesia.
Yanurita DwihapsariDepartment of Physics, Faculty of Science and Data Analytics, Sepuluh Nopember Institute of Technology (ITS), Kampus ITS Sukolilo, Surabaya, East Java, Indonesia.
Toshioh FujibuchiDepartment of Health Sciences, Division of Medical Quantum Sciences, Faculty of Medical Sciences, Kyushu University, Fukuoka, Japan.
Geoff DoughertyDepartment of Applied Physics and Medical Imaging, California State University Channel Islands, Camarillo, CA, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: The slice spacing has a crucial role in the accuracy of computed tomography (CT) images in sagittal and coronal planes. However, there is no practical method for measuring the accuracy of the slice spacing. Purpose: This study proposes a novel method to automatically measure the slice spacing using the American Association of Physicists in Medicine (AAPM) CT performance phantom. Methods: The AAPM CT performance phantom module 610-04 was used to measure slice spacing. The process of slice spacing measurement involves a pair of axial images of the module containing ramp aluminum objects located at adjacent slice positions. The middle aluminum plate of each image was automatically segmented. Next, the two segmented images were combined to produce one image with two stair objects. The centroid coordinates of two stair objects were automatically determined. Subsequently, the distance between these two centroids was measured to directly indicate the slice spacing. For comparison, the slice spacing was calculated by accessing the slice position attributes from the DICOM header of both images. The proposed method was tested on phantom images with variations in slice spacing and field of view (FOV). Results: The results showed that the automatic measurement of slice spacing was quite accurate for all variations of slice spacing and FOV, with average differences of 9.0% and 9.3%, respectively. Conclusion: A new automated method for measuring the slice spacing using the AAPM CT phantom was successfully demonstrated and tested for variations of slice spacing and FOV. Slice spacing measurement may be considered an additional parameter to be checked in addition to other established parameters.

Indexed as

American Association of Physicists in Medicine phantomcomputed tomographyimage qualityQAslice spacing

Identifiers

PMID38828077
PMCPMC11141755

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.