Evidence map›Paper›PMID 38827752›Full record

ArticleClinics in orthopedic surgery2024

Anterolateral Dual Plate Fixation for Distal Metaphyseal-Diaphyseal Junction Fractures of the Humerus: Biomechanical Finite Element Analysis with Clinical Results.

Cheungsoo Ha, Inrak Choi, Jun-Ku Lee, Jongbeom Oh, Wooyeol Ahn, Soo-Hong Han

Abstract read
In one paragraph

Article in Clinics in orthopedic surgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Cheungsoo HaDepartment of Orthopaedic Surgery, CHA Bundang Medical Center, CHA University School of Medicine, Seongnam, Korea.ORCID https://orcid.org/0000-0003-2027-0625
Inrak ChoiIntuitive Surgical Inc., Sunnyvale, CA, USA.ORCID https://orcid.org/0000-0002-5102-7209
Jun-Ku LeeDepartment of Orthopaedic Surgery, National Health Insurance Service Ilsan Hospital, Goyang, Korea.ORCID https://orcid.org/0000-0003-4640-9357
Jongbeom OhDepartment of Orthopaedic Surgery, CHA Bundang Medical Center, CHA University School of Medicine, Seongnam, Korea.ORCID https://orcid.org/0000-0003-1687-3730
Wooyeol AhnDepartment of Orthopaedic Surgery, CHA Bundang Medical Center, CHA University School of Medicine, Seongnam, Korea.ORCID https://orcid.org/0000-0001-5664-222X
Soo-Hong HanDepartment of Orthopaedic Surgery, CHA Bundang Medical Center, CHA University School of Medicine, Seongnam, Korea.ORCID https://orcid.org/0000-0002-8951-650X

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Distal metaphyseal-diaphyseal junction fractures of the humerus are a subset of injuries between humeral shaft fractures and distal intra-articular humerus fractures. A lack of space for distal fixation and the unique anatomy of concave curvature create difficulties during operative treatment. The closely lying radial nerve is another major concern. The aim of this study was to determine whether anterolateral dual plate fixation could be effective for a distal junctional fracture of the humerus both biomechanically and clinically. Methods: A right humerus 3-dimensional (3D) model was obtained based on plain radiographs and computed tomography data of patients. Two fractures, a spiral type and a spiral wedge type, were constructed. Three-dimensional models of locking compression plates and screws were constructed using materials provided by the manufacturer. The experiment was conducted by using COMSOL Multiphysics, a finite element analysis, solver, and simulation software package. For the clinical study, from July 2008 to March 2021, a total of 72 patients were included. Their medical records were retrospectively reviewed to obtain patient demographics, elbow range of motion, Disabilities of the Arm, Shoulder and Hand (DASH) scores, Mayo Elbow Performance Scores (MEPS), and hand grip strength. Results: No fracture fixation construct completely restored stiffness comparable to the intact model in torsion or compression. Combinations of the 7-hole and 5-hole plates and the 8-hole and 6-hole plates showed superior structural stiffness and stress than those with single lateral plates. At least 3 screws (6 cortices) should be inserted into the lateral plate to reduce the load effectively. For the anterior plate, it was sufficient to purchase only the near cortex. Regarding clinical results of the surgery, the range of motion showed satisfactory results in elbow flexion, elbow extension, and forearm rotation. The average DASH score was 4.3 and the average MEPS was 88.2. Conclusions: Anterolateral dual plate fixation was biomechanically superior to the single-plate method in the finite element analysis of a distal junctional fracture of the humerus model. Anterolateral dual plate fixation was also clinically effective in a large cohort of patients with distal junctional fractures of the humerus.

Indexed as

Bone PlatesFinite Element AnalysisFracture Fixation, InternalHumeral FracturesAdultAgedBiomechanical PhenomenaFemaleHumansHumerusMaleMiddle AgedRange of Motion, ArticularRetrospective StudiesBiomechanicsClinical outcomeComputational modellingFinite element analysisHumeral fractures

Identifiers

PMID38827752
PMCPMC11130622

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked