ArticleResuscitation plus2024

A new physiological manikin to test and compare ventilation devices during cardiopulmonary resuscitation.

François Morin, Laura Polard, Emeline Fresnel, Mathéo Richard, Hugo Schmit, Clarisse Martin-Houitte, Ricardo Luiz Cordioli, Marius Lebret, Alain Mercat, François Beloncle and 3 more

Abstract read
In one paragraph

Article in Resuscitation plus, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

13 authors.

François MorinDepartment of Emergency Medicine, University Hospital of Angers, Angers, France.
Laura PolardVent'Lab, University Hospital of Angers, Angers, France.
Emeline FresnelKernel Biomedical, Bois-Guillaume, France.
Mathéo RichardINOSystems, Antony, France.
Hugo SchmitDepartment of Emergency Medicine, Annecy Genevois Hospital, Annecy, France.
Clarisse Martin-HouitteDepartment of Emergency Medicine, University Hospital of Angers, Angers, France.
Ricardo Luiz CordioliHospital Israelita Albert Einstein, São Paulo, SP, Brazil.
Marius LebretVent'Lab, University Hospital of Angers, Angers, France.
Alain MercatVent'Lab, University Hospital of Angers, Angers, France.
François BeloncleVent'Lab, University Hospital of Angers, Angers, France.
Dominique SavaryDepartment of Emergency Medicine, University Hospital of Angers, Angers, France.
Jean-Christophe RichardVent'Lab, University Hospital of Angers, Angers, France.
Arnaud LesimpleVent'Lab, University Hospital of Angers, Angers, France.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: There is a lack of bench systems permitting to evaluate ventilation devices in the specific context of cardiac arrest. Objectives: The objective of the study is to assess if a new physiological manikin may permit to evaluate the performances of medical devices dedicated to ventilation during cardiopulmonary resuscitation (CPR). Methods: Specific CPR-related features required to reproduce realistic ventilation were implemented into the SAM (Sarthe Anjou Mayenne) manikin. In the first place, the manikin ability to mimic ventilation during CPR was assessed and compared to real-life tracings of airway pressure, flow and capnogram from three out of hospital cardiac arrest (OHCA) patients. In addition, to illustrate the interest of this manikin, ventilation was evaluated during mechanical continuous chest compressions with two devices dedicated to CPR: the Boussignac cardiac arrest device (B-card - Vygon; Ecouen France) and the Impedance Threshold Device (ITD - Zoll; Chelmsford, MA). Results: The SAM manikin enabled precise replication of ventilation tracings as observed in three OHCA patients during CPR, and it allowed for comparison between two distinct ventilation devices. B-card generated a mean, maximum and minimum intrathoracic pressure of 6.3 (±0.1) cmH Conclusion: The SAM manikin is an innovative model integrating specific physiological features that permit to accurately evaluate and compare ventilation devices during CPR.

Indexed as

Cardiac arrestCardiopulmonary resuscitationFunctional residual capacityIntrathoracic airway closureManikinVentilation

Identifiers

PMID38827273
PMCPMC11143906

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.