Evidence map›Paper›PMID 38826630›Full record

ArticleInnovative surgical sciences2024

Realtime assessment of vascular occlusion and reperfusion in animal models of intraoperative imaging - a pilot study.

Jayanth Kandukuri, Aseem Jain, Parag Karmarkar, Hrishikesh Gadagkar, Harold Aberman, Qihong Wang, Abhishek Rege

Abstract read
In one paragraph

Article in Innovative surgical sciences, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Jayanth KandukuriVasoptic Medical, Inc., Columbia, MD, USA.
Aseem JainVasoptic Medical, Inc., Columbia, MD, USA.
Parag KarmarkarVasoptic Medical, Inc., Columbia, MD, USA.
Hrishikesh GadagkarVasoptic Medical, Inc., Columbia, MD, USA.
Harold AbermanNoble Life Sciences, Inc., Sykesville, MD, USA.
Qihong WangDepartment of Pediatrics, University of Maryland School of Medicine, Baltimore, MD, USA.
Abhishek RegeVasoptic Medical, Inc., Columbia, MD, USA.

Funding

Real Time Noninvasive Monitoring of Blood Flow During SurgeryR44EB019856 · NIBIB · VASOPTIC MEDICAL, INC. · PI REGE, ABHISHEK · 2017 to 2018
$1.5M
NIBIB NIH HHS R44 EB019856
6 · The paper itself

Abstract

Objectives: Intraoperative monitoring of blood flow (BF) remains vital to guiding surgical decisions. Here, we report the use of SurgeON™ Blood Flow Monitor (BFM), a prototype system that attaches to surgical microscopes and implements laser speckle contrast imaging (LSCI) to noninvasively obtain and present vascular BF information in real-time within the microscope's eyepiece. Methods: The ability of SurgeON BFM to monitor BF status during reversible vascular occlusion procedures was investigated in two large animal models: occlusion of saphenous veins in six NZW rabbit hindlimbs and clipping of middle cerebral artery (MCA) branches in four Dorset sheep brain hemispheres. SurgeON BFM acquired, presented, and stored LSCI-based blood flow velocity index (BFVi) data and performed indocyanine green video angiography (ICG-VA) for corroboration. Results: Stored BFVi data were analyzed for each phase: pre-occlusion (baseline), with the vessel occluded (occlusion), and after reversal of occlusion (re-perfusion). In saphenous veins, BFVi relative to baseline reduced to 5.2±3.7 % during occlusion and returned to 102.9±14.9 % during re-perfusion. Unlike ICG-VA, SurgeON BFM was able to monitor reduced BFVi and characterize re-perfusion robustly during five serial occlusion procedures conducted 2-5 min apart on the same vessel. Across four sheep MCA vessels, BFVi reduced to 18.6±7.7 % and returned to 120.1±27.8 % of baseline during occlusion and re-perfusion phases, respectively. Conclusions: SurgeON BFM can noninvasively monitor vascular occlusion status and provide intuitive visualization of BF information in real-time to an operating surgeon. This technology may find application in vascular, plastic, and neurovascular surgery.

Indexed as

augmented reality visualizationblood flow imagingnoninvasive monitoringreal-time feedbacksurgical technology

Identifiers

PMID38826630
PMCPMC11138401

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.