ArticleRadiation oncology (London, England)2024

Evaluation of multiple-vendor AI autocontouring solutions.

Lee Goddard, Christian Velten, Justin Tang, Karin A Skalina, Robert Boyd, William Martin, Amar Basavatia, Madhur Garg, Wolfgang A Tomé

Abstract readEvaluation Study
In one paragraph

Article in Radiation oncology (London, England), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Review
  5. Article
  6. Article
  7. Review
  8. Article
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Lee GoddardDepartment of Radiation Oncology, Montefiore Medical Center, Bronx, NY, 10467, USA.
Christian VeltenDepartment of Radiation Oncology, Montefiore Medical Center, Bronx, NY, 10467, USA.
Justin TangDepartment of Radiation Oncology, Montefiore Medical Center, Bronx, NY, 10467, USA.
Karin A SkalinaDepartment of Radiation Oncology, Montefiore Medical Center, Bronx, NY, 10467, USA.
Robert BoydDepartment of Radiation Oncology, Montefiore Medical Center, Bronx, NY, 10467, USA.
William MartinDepartment of Radiation Oncology, Montefiore Medical Center, Bronx, NY, 10467, USA.
Amar BasavatiaDepartment of Radiation Oncology, Montefiore Medical Center, Bronx, NY, 10467, USA.
Madhur GargDepartment of Radiation Oncology, Montefiore Medical Center, Bronx, NY, 10467, USA.
Wolfgang A ToméDepartment of Radiation Oncology, Montefiore Medical Center, Bronx, NY, 10467, USA. wolfgang.tome@einsteinmed.edu.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundMultiple artificial intelligence (AI)-based autocontouring solutions have become available, each promising high accuracy and time savings compared with manual contouring. Before implementing AI-driven autocontouring into clinical practice, three commercially available CT-based solutions were evaluated. MATERIALS AND

methodsThe following solutions were evaluated in this work: MIM-ProtégéAI+ (MIM), Radformation-AutoContour (RAD), and Siemens-DirectORGANS (SIE). Sixteen organs were identified that could be contoured by all solutions. For each organ, ten patients that had manually generated contours approved by the treating physician (AP) were identified, totaling forty-seven different patients. CT scans in the supine position were acquired using a Siemens-SOMATOMgo 64-slice helical scanner and used to generate autocontours. Physician scoring of contour accuracy was performed by at least three physicians using a five-point Likert scale. Dice similarity coefficient (DSC), Hausdorff distance (HD) and mean distance to agreement (MDA) were calculated comparing AI contours to "ground truth" AP contours.

resultsThe average physician score ranged from 1.00, indicating that all physicians reviewed the contour as clinically acceptable with no modifications necessary, to 3.70, indicating changes are required and that the time taken to modify the structures would likely take as long or longer than manually generating the contour. When averaged across all sixteen structures, the AP contours had a physician score of 2.02, MIM 2.07, RAD 1.96 and SIE 1.99. DSC ranged from 0.37 to 0.98, with 41/48 (85.4%) contours having an average DSC ≥ 0.7. Average HD ranged from 2.9 to 43.3 mm. Average MDA ranged from 0.6 to 26.1 mm.

conclusionsThe results of our comparison demonstrate that each vendor's AI contouring solution exhibited capabilities similar to those of manual contouring. There were a small number of cases where unusual anatomy led to poor scores with one or more of the solutions. The consistency and comparable performance of all three vendors' solutions suggest that radiation oncology centers can confidently choose any of the evaluated solutions based on individual preferences, resource availability, and compatibility with their existing clinical workflows. Although AI-based contouring may result in high-quality contours for the majority of patients, a minority of patients require manual contouring and more in-depth physician review.

Indexed as

Artificial IntelligenceRadiotherapy Planning, Computer-AssistedTomography, X-Ray ComputedAlgorithmsHumansImage Processing, Computer-AssistedOrgans at RiskAIAutocontouring

Identifiers

PMID38822385
PMCPMC11143643

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.