Evidence map›Paper›PMID 38819666›Full record

ArticleInternational orthopaedics2024

Robotic-assisted patellofemoral arthroplasty provides excellent implant survivorship and high patient satisfaction at mid-term follow-up.

Giacomo Pacchiarotti, Alessandro Todesca, Michele Coppola, Stefano Gumina

Abstract read
In one paragraph

Article in International orthopaedics, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed, 2 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 2 syntheses or guidelines pooled it.

  1. Pooled it
  2. Pooled it
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Giacomo PacchiarottiDepartment of Anatomy, Histology, Legal Medicine, and Orthopaedics, Sapienza University of Rome, Rome, Italy. giacomo.pacchiarotti@uniroma1.it.ORCID 0000-0001-9718-8027
Alessandro TodescaIstituto Chirurgico Ortopedico Traumatologico (ICOT), Latina, Italy.
Michele CoppolaIstituto Chirurgico Ortopedico Traumatologico (ICOT), Latina, Italy.
Stefano GuminaDepartment of Anatomy, Histology, Legal Medicine, and Orthopaedics, Sapienza University of Rome, Rome, Italy.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeRobotic adoption in knee surgery has yielded several benefits, but its application in patellofemoral arthroplasty (PFA) remains barely reported. The purpose of this study was to determine implant survival, patient satisfaction, and functional outcomes after robotic-assisted PFA at an intermediate follow-up.

methodsThis prospective analysis targeted 18 knees of 16 consecutive patients who underwent robot-aided PFA with three-year minimum follow-up (range, 3 to 6 years). Each patient was evaluated collecting pre-operative and post-operative medical record data, including range of motion, radiographic images, and multiple scores, such as VAS, APKS, and OKS.

resultsAt surgery, the mean age was 55.4 years ± 14.4 (range, 32 to 78 years), and the mean BMI was 26.8 kg/m² ±5.2 (range, 20 to 36). Etiologies of patellofemoral osteoarthritis included idiopathic degeneration (28%), post-traumatic (33%), and dysplasia (39%). Pre-implantation scores were VAS 7.9 ± 1.4, AKPS 34.6 ± 23.3, and OKS 17.3 ± 10.3. One implant was revised with primary total knee arthroplasty for osteoarthritis progression. Clinical and radiographic follow-up showed no signs of loosening or infection. The maximum flexion reached an average of 131.1°±10.5° (range, 110° to 145°), accompanied by significantly improved score results (P-value < 0.01): VAS 1.1 ± 1.4, AKPS 90.2 ± 8.6, and OKS 46.3 ± 1.8.

conclusionsAt 3 years after robotic assisted patellofemoral arthroplasty, excellent implant survival and patient satisfaction rates can be expected along with significantly improved functional and pain control outcomes. Although the limitations imposed by the restricted cohort, these findings indicate that robotic assistance in PFA is both safe and effective at intermediate follow-up.

Indexed as

Arthroplasty, Replacement, KneeKnee ProsthesisPatellofemoral JointPatient SatisfactionRobotic Surgical ProceduresAdultAgedFemaleFollow-Up StudiesHumansMaleMiddle AgedOsteoarthritis, KneeProspective StudiesProsthesis FailureRange of Motion, ArticularPartial knee arthroplastyPatellofemoral ArthroplastyPatellofemoral OsteoarthritisRobotic-assisted surgeryUnicompartimental Arthroplasty

Identifiers

PMID38819666
PMCPMC11246259

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.