Evidence map›Paper›PMID 38818673›Full record

ArticleMagnetic resonance in medicine2024

Modeling and measurement of lead tip heating and resonant length for implanted, insulated wires.

Lydia J Bardwell Speltz, Seung-Kyun Lee, Yunhong Shu, Matthew R Tarasek, Joshua D Trzasko, Thomas K F Foo, Matt A Bernstein

Abstract read
In one paragraph

Article in Magnetic resonance in medicine, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Lydia J Bardwell SpeltzDepartment of Radiology, Mayo Clinic, Rochester, Minnesota, USA.ORCID 0000-0003-4940-4148
Seung-Kyun LeeTechnology and Innovation Center, GE HealthCare, GE Research, Niskayuna, New York, USA.
Yunhong ShuDepartment of Radiology, Mayo Clinic, Rochester, Minnesota, USA.
Matthew R TarasekTechnology and Innovation Center, GE HealthCare, GE Research, Niskayuna, New York, USA.
Joshua D TrzaskoDepartment of Radiology, Mayo Clinic, Rochester, Minnesota, USA.
Thomas K F FooTechnology and Innovation Center, GE HealthCare, GE Research, Niskayuna, New York, USA.
Matt A BernsteinDepartment of Radiology, Mayo Clinic, Rochester, Minnesota, USA.ORCID 0000-0003-3770-0441

Funding

High-performance compact 3T MRI: Technical optimization for advanced brain imagingU01EB024450 · NIBIB · MAYO CLINIC ROCHESTER · PI BERNSTEIN, MATTHEW A., FOO, THOMAS K · 2017 to 2021
$5.3M
NIBIB NIH HHS U01 EB024450NIH HHS U01EB024450
6 · The paper itself

Abstract

purposeTo study implant lead tip heating because of the RF power deposition by developing mathematical models and comparing them with measurements acquired at 1.5 T and 3 T, especially to predict resonant length. THEORY AND

methodsA simple exponential model and an adapted transmission line model for the electric field transfer function were developed. A set of wavenumbers, including that calculated from insulated antenna theory (King wavenumber) and that of the embedding medium were considered. Experiments on insulated, capped wires of varying lengths were performed to determine maximum temperature rise under RF exposure. The results are compared with model predictions from analytical expressions derived under the assumption of a constant electric field, and with those numerically calculated from spatially varying, simulated electric fields from body coil transmission. Simple expressions for the resonant length bounded between one-quarter and one-half wavelength are developed based on the roots of transcendental equations.

resultsThe King wavenumber for both models more closely matched the experimental data with a maximum root mean square error of 9.81°C at 1.5 T and 5.71°C at 3 T compared to other wavenumbers with a maximum root mean square error of 27.52°C at 1.5 T and 22.01°C for 3 T. Resonant length was more accurately predicted compared to values solely based on the embedding medium.

conclusionAnalytical expressions were developed for implanted lead heating and resonant lengths under specific assumptions. The value of the wavenumber has a strong effect on the model predictions. Our work could be used to better manage implanted device lead tip heating.

Indexed as

Hot TemperatureComputer SimulationElectrodes, ImplantedEquipment DesignEquipment Failure AnalysisHumansMagnetic Resonance ImagingModels, TheoreticalProstheses and Implantsimplanted devicesMR safetyresonant lengthRF heatingwavenumber

Identifiers

PMID38818673
PMCPMC11414523

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.