Evidence map›Paper›PMID 38817650›Full record

ArticleWorld journal of cardiology2024

Evaluation of mitral chordae tendineae length using four-dimensional computed tomography.

Takuya Mori, Satoshi Matsushita, Terumasa Morita, Abulaiti Abudurezake, Junji Mochizuki, Atsushi Amano

Abstract read
In one paragraph

Article in World journal of cardiology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Takuya MoriDepartment of Cardiovascular Surgery, Juntendo University Faculty of Medicine, Tokyo 113-8421, Japan.
Satoshi MatsushitaDepartment of Cardiovascular Surgery, Juntendo University Faculty of Medicine, Tokyo 113-8421, Japan. saty-m@juntendo.ac.jp.
Terumasa MoritaDepartment of Cardiovascular Surgery, Juntendo University Faculty of Medicine, Tokyo 113-8421, Japan.
Abulaiti AbudurezakeDepartment of Cardiovascular Surgery, Juntendo University Faculty of Medicine, Tokyo 113-8421, Japan.
Junji MochizukiDepartment of Radiology, Minamino Cardiovascular Hospital, Tokyo 192-0918, Japan.
Atsushi AmanoDepartment of Cardiovascular Surgery, Juntendo University Faculty of Medicine, Tokyo 113-8421, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundMitral valvuloplasty using artificial chordae tendineae represents an effective surgical approach for treating mitral regurgitation. Achieving precise measurements of artificial chordae tendineae length (CL) is an important factor in the procedure; however, no objective index currently exists to facilitate this measurement. Therefore, preoperative assessment of CL is critical for surgical planning and support. Four-dimensional x-ray micro-computed tomography (4D-CT) may be useful for accurate CL measurement considering that it allows for dynamic three-dimensional (3D) evaluation compared to that with transthoracic echocardiography, a conventional inspection method.

aimTo investigate the behavior and length of mitral chordae tendineae during systole using 4D-CT.

methodsEleven adults aged > 70 years without mitral valve disease were evaluated. A 64-slice CT scanner was used to capture 20 phases in the cardiac cycle in electrocardiographic synchronization. The length of the primary chordae tendineae was measured from early systole to early diastole using the 3D image. The primary chordae tendineae originating from the anterior papillary muscle and attached to the A1-2 region and those from the posterior papillary muscle and attached to the A2-3 region were designated as cA and cP, respectively. The behavior and maximum lengths [cA (ma), cP (max)] were compared, and the correlation with body surface area (BSA) was evaluated.

resultsIn all cases, the mitral anterior leaflet chordae tendineae could be measured. In most cases, the cA and cP chordae tendineae could be measured visually. The mean cA (max) and cP (max) were 20.2 mm ± 1.95 mm and 23.5 mm ± 4.06 mm, respectively. cP (max) was significantly longer. The correlation coefficients (r) with BSA were 0.60 and 0.78 for cA (max) and cP (max), respectively. Both cA and cP exhibited constant variation in CL during systole, with a maximum 1.16-fold increase in cA and a 1.23-fold increase in cP from early to mid-systole. For cP, CL reached a plateau at 15% and remained elongated until end-systole, whereas for cA, after peaking at 15%, CL shortened slightly and then moved toward its peak again as end-systole approached.

conclusionThe study suggests that 4D-CT is a valuable tool for accurate measurement of both the length and behavior of chordae tendineae within the anterior leaflet of the mitral valve.

Indexed as

Cardiac cycleChordae tendineaeComputed tomographyFour-dimensionalMitral valve

Identifiers

PMID38817650
PMCPMC11135327

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.