Evidence map›Paper›PMID 38816587›Full record

ArticleJournal of patient-reported outcomes2024

Crosswalk between the PROMIS physical function CAT and PROMIS upper extremity CAT v1.2 in a hand surgery population.

Miranda J Rogers, Joshua R Daryoush, Chong Zhang, Amy Cizik, Angela P Presson, Nikolas H Kazmers

Abstract read
In one paragraph

Article in Journal of patient-reported outcomes, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Miranda J Rogers *Department of Orthopaedic Surgery, University of Michigan, Ann Arbor, MI, 48109, USA.
Joshua R Daryoush *Department of Orthopaedic Surgery, University of Utah, 590 Wakara Way, Salt Lake City, UT, 84108, USA.
Chong ZhangDivision of Public Health, University of Utah, Salt Lake City, UT, 84108, USA.
Amy CizikDepartment of Orthopaedic Surgery, University of Utah, 590 Wakara Way, Salt Lake City, UT, 84108, USA.
Angela P PressonDivision of Public Health, University of Utah, Salt Lake City, UT, 84108, USA.
Nikolas H KazmersDepartment of Orthopaedic Surgery, University of Utah, 590 Wakara Way, Salt Lake City, UT, 84108, USA. nkazmers@gmail.com.ORCID 0000-0002-3685-1662

Funding

Utah Center for Clinical and Translational ScienceUL1TR002538 · NCATS · UNIVERSITY OF UTAH · PI HESS, RACHEL, MAJERSIK, JENNIFER JUHL · 2018 to 2022
$26.0M
CTSA UM1 Program at University of UtahUM1TR004409 · NCATS · UTAH STATE HIGHER EDUCATION SYSTEM--UNIVERSITY OF UTAH · PI RACHEL HESS, Jennifer Juhl Majersik · 2023 to 2026
$21.9M
Foundation for the National Institutes of Health UL1TR002538NCATS NIH HHS UL1 TR002538NCATS NIH HHS UM1 TR004409
6 · The paper itself

Abstract

backgroundThere is no gold standard patient-reported outcome measure (PROM) in hand surgery. As a result, a diverse array of PROM instruments have been utilized across centers over time. Lack of score interchangeability limits the ability to compare or conglomerate scores when new instruments are introduced. Our aim was to develop a linkage for the PROMIS UE CAT v1.2 and PROMIS PF CAT scores and develop crosswalk tables for interconversion between these PROMs.

methodsRetrospective review was conducted to identify adult (≥ 18y) patients seen by orthopaedic hand surgeons at a single academic tertiary care hospital who had completed PROMIS UE CAT v1.2 and PROMIS PF CAT score at the same visit. For those with multiple visits, only one randomly selected visit was included in the analyses. Pearson's correlation was calculated to determine the linear relationship between the scores. Linkage from PF to UE was performed utilizing several commonly utilized equating models (identity, mean, linear, equipercentile and circle-arc methods). The performance of the models was assessed using intraclass correlation (ICC) between observed PROMIS UE CAT v1.2 and estimated PROMIS UE CAT v1.2 scores generated using the model as well as Root Mean Square Error (RMSE). The model chosen as the 'best' was further assessed for population invariance using root expected mean squared difference (REMSD) where < 0.08 were considered good.

resultsOf 10,081 included patients, mean age was 48.3 (SD = 17.0), and 54% were female (5,477/10,081). Mean UE CAT v1.2 and PF CAT scores were 37 (SD = 9.8) and 46 (SD = 10.0), respectively. There was a strong correlation between the scores (Pearson correlation r = 0.70). All methods performed acceptably (ICC ≥ 0.66 and RMSE < = 7.52 for all). The equipercentile method had the highest ICC (ICC = 0.70 (95% CI 0.69-0.71)) while the mean and circle arc methods had the lowest RMSE. The circle arc method is the most reliable with the smallest standard error and has satisfactory population invariance across age group (REMSD 0.065) and sex (REMSD 0.036).

conclusionsCrosswalk tables to be used for bidirectional conversion between scores were created. LEVEL OF EVIDENCE: III.

Indexed as

HandPatient Reported Outcome MeasuresAdultAgedFemaleHumansMaleMiddle AgedRetrospective StudiesUpper ExtremityComputer adaptive testingCrosswalk studyPatient-reported outcome measuresPatient-reported outcomes measurement information systemPhysical functionPROMPROMIS-PFPROMIS-UE CATUpper extremity

Identifiers

PMID38816587
PMCPMC11139816

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.