Evidence map›Paper›PMID 38814381›Full record

ArticleSpine deformity2024

Validation of a new method for the radiological measurement of rod curvature in patients with spine deformity.

Daniel Larrieu, Alice Baroncini, Ayman Assi, Cecile Roscop, Louis Boissiere, Ibrahim Obeid

Abstract readValidation Study
PubMed Publisher
In one paragraph

Article in Spine deformity, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Daniel LarrieuSpine Surgery Unit 1, Bordeaux University Pellegrin Hospital, Bordeaux, France.
Alice BaronciniIRCCS Ospedale Galeazzi - Sant'Ambrogio, Milan, Italy. Alice.baroncini@gmail.com.ORCID 0000-0002-4383-3470
Ayman AssiSaint Joseph University of Beirut, Beirut, Lebanon.
Cecile RoscopSpine Surgery Unit 1, Bordeaux University Pellegrin Hospital, Bordeaux, France.
Louis BoissiereSpine Surgery Unit 1, Bordeaux University Pellegrin Hospital, Bordeaux, France.
Ibrahim ObeidSpine Surgery Unit 1, Bordeaux University Pellegrin Hospital, Bordeaux, France.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThe relationship between rod curvature and postoperative radiographic results is a debated topic. One of the reasons of the heterogeneity of the observed results might reside in the lack of a validated and widely employed method to measure the curvature of the rods. Aim of this study was to present and validate a novel method for rod measurement, which is based on routine X-rays and utilizes a regression algorithm that limits manual measurements and the related errors.

methodsData from 20 adolescent idiopathic scoliosis/Scheuermann kyphosis (AIS/SK) patients and 35 adult spine deformity (ASD) patients for analysis, with 112 rods in total. An orthogonal reference grid was overlaid on the lateral X-ray; seven points were then marked along each rod and their coordinates recorded in a table. Using these coordinates, a third-order polynomial regression was applied to obtain the rod curvature equation (correlation coefficients > 0.97). Three observers (one surgeon, one experienced and one inexperienced observer) independently applied the developed method to measure the rod angulation of the included patients and performed the measurements twice. The reliability of the method was evaluated in terms of intraclass correlation coefficient (ICC), Bland-Altmann plot and 2S

resultsThe intra-observer ICCs for all measurements exceed 0.85, indicating an excellent correlation. For the AIS/SK group, the surgeon showed a slightly lower reliability compared to the other two evaluators (0.93 vs 0.98 and 0.98). However, the surgeon showed a higher reliability in measurements of the rods at the lumbar level, both for L1-S1 and L4-S1 (0.98 vs 0.96 and 0.89; 0.97 vs. 0.85 and 0.91, respectively). The variability also showed excellent results, with a mean variability ranging from 1.09° to 3.76°. The inter-observer ICCs for the three measurement groups showed an excellent reliability for the AIS/SK group (0.98). The reliability was slightly lower but still excellent for the lumbar measurements in ASD patients at L1-S1 (0.89) and L4-S1 (0.83). The results of the 2S

conclusionThe described method represents a reliable and reproducible way to measure rod curvature. This method is based on routine X-rays and utilizes a regression algorithm that limits manual measurements and the related errors.

Indexed as

RadiographyScoliosisAdolescentAdultAlgorithmsFemaleHumansKyphosisMaleObserver VariationReproducibility of ResultsScheuermann DiseaseSpinal FusionSpineYoung AdultMeasurement methodRod curvatureRod measurementScoliosisSpine deformity

Identifiers

PMID38814381

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.