ArticleAnalytical chemistry2024
Surface Acoustic Wave-Driven Enhancement of Enzyme-Linked Immunosorbent Assays: ELISAW.
Article in Analytical chemistry, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
7 citing papers in PubMed.
- Lab-on-a-chip device with an integrated surface acoustic wave micromixer for enhanced porous silicon biosensor performance.RSC advances · 2026Article
- A Metamaterial Buckling-Assisted Surface-Acoustic-Wave Enabled Sensor (mBASES) for Versatile and Ultrasensitive Biomarker Detection.Advanced materials (Deerfield Beach, Fla.) · 2026Article
- Acoustofluidic Biosensors.Micromachines · 2026Review
- Stimuli-Responsive Colloidal Gate for Active Modulation of Fluid Flow in Packed Beds.Langmuir : the ACS journal of surfaces and colloids · 2025Article
- Review
- Extracellular vesicle-based point-of-care testing for diagnosis and monitoring of Alzheimer's disease.Microsystems & nanoengineering · 2025Article
- Acoustofluidics: Technology Advances and Applications from 2022 to 2024.Analytical chemistry · 2025Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
Abstract
Enzyme-linked immunosorbent assays (ELISAs) are widely used in biology and clinical diagnosis. Relying on antigen-antibody interaction through diffusion, the standard ELISA protocol can be time-consuming, preventing its use in rapid diagnostics. We present a time-saving and more sensitive ELISA without changing the standard setup and protocol, using surface acoustic waves (SAWs) to enhance performance. Each step of the assay, from the initial antibody binding onto the walls of the well plate to the target analyte molecules' binding for detection─except, notably, for the blocking step─is improved principally via acoustic streaming-driven advection. Using SAWs, the time required for one step of an example ELISA is reduced from 60 to 15 min to achieve the same binding amount. By extending the duration of SAW exposure to 20 min, the sensitivity can be significantly improved over the 60 min, 35 °C ELISA without SAWs. It is also possible to confer beneficial improvements to bead-based ELISA by combining it with SAWs to further reduce the time required for binding to 2 min. By significantly increasing the speed of ELISA, its utility may be improved for a wide range of point-of-care diagnostics applications.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials