Temperature Changes in the Pulp Chamber During Orthodontic Bonding Using a High-Power Light-Emitting Diode Device With Two Different Exposure Times and Intensities: An In-Vitro Study.
Article in Cureus, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- A comparative in vitro study on monomer release from flash-free or conventional bonding systems.Clinical oral investigations · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectiveThis study used a high-power light-emitting diode (LED) device to evaluate the effects of two exposure times and intensities on pulp chamber temperature and cooling time during bracket bonding. MATERIALS AND
methodsSixty upper premolars were used in the sample in this study. These premolars were split into two main groups based on the exposure time and intensity: the first group employed a traditional curing mode (TCG) for 20 seconds with an intensity of 1200 mw/cm
resultsThe two groups had statistically significant differences regarding the temperature increase in the pulp chamber and cooling time (p > 0.001). The mean temperature increase in the traditional curing group was 3.52°C, which is greater than that in the quick curing group (i.e., a mean value of 1.28°C). The mean cooling time in the traditional curing group was 38.83 seconds, which is greater than that in the quick curing group (9.97 seconds).
conclusionsReducing the exposure time to 3 seconds and increasing the intensity to 2500 mw/cm