Evidence map›Paper›PMID 38812953›Full record

ArticleNorth American Spine Society journal2024

Impact of bone density and integrated screw configuration on standalone anterior lumbar interbody construct strength.

Ross Dies, Jay Manuel, Andrew S Zhang, Milan Mody, Seokgi Lee, Mathew Root, Trevor Carroll, Chukwuemeka Mbagwu, Giovanni F Solitro

Abstract read
In one paragraph

Article in North American Spine Society journal, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Ross DiesDepartment of Orthopaedic Surgery, Louisiana State University Health Sciences Center at Shreveport, 1501 Kings Highway, Shreveport, LA 71103, Unites States.
Jay ManuelDepartment of Orthopaedic Surgery, Louisiana State University Health Sciences Center at Shreveport, 1501 Kings Highway, Shreveport, LA 71103, Unites States.
Andrew S ZhangDepartment of Orthopaedic Surgery, Louisiana State University Health Sciences Center at Shreveport, 1501 Kings Highway, Shreveport, LA 71103, Unites States.
Milan ModyDepartment of Orthopaedic Surgery, Louisiana State University Health Sciences Center at Shreveport, 1501 Kings Highway, Shreveport, LA 71103, Unites States.
Seokgi LeeRayen School of Engineering, Youngstown State University, 1 Tressel Way, Youngstown, OH 44555, United States.
Mathew RootDepartment of Orthopaedic Surgery, Louisiana State University Health Sciences Center at Shreveport, 1501 Kings Highway, Shreveport, LA 71103, Unites States.
Trevor CarrollDepartment of Orthopaedic Surgery, Louisiana State University Health Sciences Center at Shreveport, 1501 Kings Highway, Shreveport, LA 71103, Unites States.
Chukwuemeka MbagwuDepartment of Orthopaedic Surgery, Louisiana State University Health Sciences Center at Shreveport, 1501 Kings Highway, Shreveport, LA 71103, Unites States.
Giovanni F SolitroDepartment of Orthopaedic Surgery, Louisiana State University Health Sciences Center at Shreveport, 1501 Kings Highway, Shreveport, LA 71103, Unites States.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: In anterior lumbar interbody fusion (ALIF), the use of integrated screws is attractive to surgeons because of the ease of implantation and no additional profile. However, the number and length of screws necessary for safe and stable implantation in various bone densities is not yet fully understood. The current study aims to determine how important both length and number of screws are for stability of ALIFs. Methods: Three bone models with densities of 10, 15, and 20 pounds per cubic foot (PCF) were chosen as surrogates. These were instrumented using the Z-Link lumbar interbody system with either 2, 3, or 4 integrated 4.5 × 20 mm screws or 4.5 × 25 mm screws (Zavation, LLC, Flowood, MS). The bone surrogates were tested with loading conditions resulting in spine extension to measure construct stiffness and peak force. Results: The failure load of the construct was influenced by the length of screws (p=.01) and density of the bone surrogate (p<.01). There was no difference in failure load between using 2 screws and 3 screws (p=.32) or when using four 20 mm screws versus three 25 mm screws (p=.295). Conclusion: In our study, both bone density and length of screws significantly affected the construct's load to failure. In certain cases where a greater number of screws are unable to be implanted, the same stability can potentially be conferred with use of longer screws. Future clinical studies should be performed to test these biomechanical results.

Indexed as

AlifAnterior lumbar interbody fusionFusionInterbody cagesOsteoporosisScrews

Identifiers

PMID38812953
PMCPMC11133976

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.