Evidence map›Paper›PMID 38812944›Full record

ArticleSaudi pharmaceutical journal : SPJ : the official publication of the Saudi Pharmaceutical Society2024

Development of a microcantilever-based biosensor for detecting Programmed Death Ligand 1.

Tajweed Neairat, Mahmoud Al-Gawati, Qura Tul Ain, Abdulaziz K Assaifan, Aws Alshamsan, Abdulaziz Alarifi, Abdullah N Alodhayb, Khalid E Alzahrani, Hamad Albrithen

Abstract read
In one paragraph

Article in Saudi pharmaceutical journal : SPJ : the official publication of the Saudi Pharmaceutical Society, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Mechano-Organ-on-Chip for Cancer Research.International journal of molecular sciences · 2026
    Review
  2. Review
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Tajweed NeairatDepartment of Physics and Astronomy, College of Science, King Saud University, Riyadh 11451, Saudi Arabia.
Mahmoud Al-GawatiDepartment of Physics and Astronomy, College of Science, King Saud University, Riyadh 11451, Saudi Arabia.
Qura Tul AinDepartment of Physics, The Women University Multan, Khawajabad, Multan, Pakistan.
Abdulaziz K AssaifanBiological and Environmental Sensing Research Unit, King Abdullah Institute for Nanotechnology, King Saud University, Riyadh, Saudi Arabia.
Aws AlshamsanDepartment of Pharmaceutics, College of Pharmacy, King Saud University, Riyadh, Saudi Arabia.
Abdulaziz AlarifiDepartment of Basic Sciences, College of Science and Health Professions, King Saud bin Abdulaziz University for Health Sciences, Riyadh, Saudi Arabia.
Abdullah N AlodhaybDepartment of Physics and Astronomy, College of Science, King Saud University, Riyadh 11451, Saudi Arabia.
Khalid E AlzahraniDepartment of Physics and Astronomy, College of Science, King Saud University, Riyadh 11451, Saudi Arabia.
Hamad AlbrithenDepartment of Physics and Astronomy, College of Science, King Saud University, Riyadh 11451, Saudi Arabia.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The ongoing global concern of cancer worldwide necessitates the development of advanced diagnostic and therapeutic strategies. The majority of recent detection strategies involve the employment of biomarkers. A critical biomarker for cancer immunotherapy efficacy and patient prognosis is Programmed Death Ligand 1 (PD-L1), which is a key immune checkpoint protein. PD-L1 can be particularly linked to cancer progression and therapy response. Current detection methods, such as enzyme-linked immunosorbent assay (ELISA), face limitations like high cost, time consumption, and complexity. This study introduces a microcantilever-based biosensor designed for the detection of soluble PD-L1 (sPD-L1), which has a specific association with PD-L1. The biosensor utilizes anti-PD-L1 as the sensing layer, capitalizing on the specific binding affinity between anti-PD-L1 and sPD-L1. The presence of the sensing layer was confirmed through Atomic Force Microscopy (AFM) and contact angle measurements. Binding between sPD-L1 and anti-PD-L1 induces a shift in the microcantilever's resonance frequency, which is proportional to the PD-L1 concentration. Notably, the resonance frequency shift demonstrates a robust linear relationship with the increasing biomarker concentration, ranging from 0.05 ng/ml to 500 ng/ml. The detection limit of the biosensor was determined to be approximately 10 pg/ml. The biosensor demonstrates excellent performance in detecting PD-L1 with high specificity even in complex biological matrices. This innovative approach not only provides a promising tool for early cancer diagnosis but also holds potential for monitoring immunotherapy efficacy, paving the way for personalized and effective cancer treatments.

Indexed as

AFMBiosensorCantilever-based sensorsProgram Death Ligand 1

Identifiers

PMID38812944
PMCPMC11134855

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.