Evidence map›Paper›PMID 38812913›Full record

ArticleFrontiers in bioengineering and biotechnology2024

Biomechanical study of a biplanar double support screw (BDSF) technique based on Pauwels angle in femoral neck fractures: finite element analysis.

Zhongjian Tang, Yazhong Zhang, Shaolong Huang, Zhexi Zhu, Chengqiang Zhou, Ziqiang Zhu, Yunqing Wang, Bin Wang

Abstract read
In one paragraph

Article in Frontiers in bioengineering and biotechnology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Zhongjian Tang *Department of Orthopaedics, The Second Affiliated Hospital of XuZhou Medical University, Xuzhou, China.
Yazhong Zhang *Department of Orthopaedics, The Second Affiliated Hospital of XuZhou Medical University, Xuzhou, China.
Shaolong Huang *Department of Orthopaedics, The Second Affiliated Hospital of XuZhou Medical University, Xuzhou, China.
Zhexi ZhuDepartment of Orthopaedics, The Second Affiliated Hospital of XuZhou Medical University, Xuzhou, China.
Chengqiang ZhouDepartment of Orthopaedics, The Second Affiliated Hospital of XuZhou Medical University, Xuzhou, China.
Ziqiang ZhuDepartment of Orthopaedics, The Second Affiliated Hospital of XuZhou Medical University, Xuzhou, China.
Yunqing WangDepartment of Orthopaedics, The Second Affiliated Hospital of XuZhou Medical University, Xuzhou, China.
Bin WangDepartment of Orthopaedics, The Second Affiliated Hospital of XuZhou Medical University, Xuzhou, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objective: The objective of the present study is to conduct a comparative analysis of the biomechanical advantages and disadvantages associated with a biplanar double support screw (BDSF) internal fixation device. Methods: Two distinct femoral neck fracture models, one with a 30° angle and the other with a 70° angle, were created using a verified and effective finite element model. Accordingly, a total of eight groups of finite element models were utilized, each implanted with different configurations of fixation devices, including distal screw 150° BDSF, distal screw 165° BDSF, 3 CLS arranged in an inverted triangle configuration, and 4 CLS arranged in a "α" configuration. Subsequently, the displacement and distribution of Von Mises stress (VMS) in the femur and internal fixation device were assessed in each fracture group under an axial load of 2100 N. Results: At Pauwels 30° Angle, the femur with a 150°-BDSF orientation exhibited a maximum displacement of 3.17 mm, while the femur with a 165°-BDSF orientation displayed a maximum displacement of 3.13 mm. When compared with the femoral neck fracture model characterized by a Pauwels Angle of 70°, the shear force observed in the 70° model was significantly higher than that in the 30° model. Conversely, the stability of the 30° model was significantly superior to that of the 70° model. Furthermore, in the 70° model, the BDSF group exhibited a maximum femur displacement that was lower than both the 3CCS (3.46 mm) and 4CCS (3.43 mm) thresholds. Conclusion: The biomechanical properties of the BDSF internal fixation device are superior to the other two hollow screw internal fixation devices. Correspondingly, superior biomechanical outcomes can be achieved through the implementation of distal screw insertion at an angle of 165°. Thus, the BDSF internal fixation technique can be considered as a viable closed reduction internal fixation technique for managing femoral neck fractures at varying Pauwels angles.

Indexed as

BDSFfemoral neck fracturefinite elementhollow screwPauwels angles