Evidence map›Paper›PMID 38812869›Full record

ArticleIndian journal of orthopaedics2024

Effect of Elevated Acetabular Cup on Contact and Failure Analysis in Hip Implants for Different Microseparations and Cup Inclinations Under Routine Gait Activities Using In Silico Approach.

R Nithyaprakash, S Shankar, R Naveenkumar, A J Kirthik Raja, R Gokul Anand, G Abbas, Chander Prakash, Alokesh Pramanik, Animesh Kumar Basak

Abstract read
In one paragraph

Article in Indian journal of orthopaedics, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

R NithyaprakashDepartment of Mechatronics Engineering, Kongu Engineering College, Erode, Tamil Nadu India.ORCID 0000-0002-9218-9300
S ShankarDepartment of Mechatronics Engineering, Kongu Engineering College, Erode, Tamil Nadu India.
R NaveenkumarDepartment of Mechanical Engineering, Kongu Engineering College, Erode, Tamil Nadu India.
A J Kirthik RajaDepartment of Mechatronics Engineering, Kongu Engineering College, Erode, Tamil Nadu India.
R Gokul AnandDepartment of Mechatronics Engineering, Kongu Engineering College, Erode, Tamil Nadu India.
G AbbasDepartment of Mechatronics Engineering, Kongu Engineering College, Erode, Tamil Nadu India.
Chander PrakashPro-Vice Chancellor, Research & Development, Chitkara University, Chandigarh, Punjab India.
Alokesh PramanikSchool of Civil and Mechanical Engineering, Curtin University, Bentley, WA Australia.
Animesh Kumar BasakAdelaide Microscopy, The University of Adelaide, Adelaide, SA 5005 Australia.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objectives: The acetabular cup design plays a critical role in reducing contact stress between femur head acetabular cup. Many studies used ellipsoidal and spheroidal geometry in acetabular cup design to effectively reduce contact stress. The present study focuses on elevated acetabular cup rim with round corner design to reduce contact stress with round corner geometry. Methods: The cobalt chromium femur head and cup are considered for finite element (FE) model of hip resurfacing. The gait loads of routine activities of humans like normal walking, stair ascending and descending and sitting down and getting up gait activities are applied to the developed 3D FE model. Five microseparations of 0.5, 1, 1.5, 2 and 2.5 mm are considered in the present study. The acetabular cup inclination angle considered for this study are 35°, 45°, 55°, 65° and 75°. The contact stress and von Mises stress plot for each gait activities under these microseparations are analyzed for betterment of longevity of implants. Results: Overall elevated cup rim design helped in reducing contact stress to a greater extent than conventional cup with different geometries. Also, the predicted von Mises stress for all the parameters considered in the current study are well within the yield strength of CoCr material. Therefore, elevated cup rim could be used as a better alternative to spline and, ellipsoidal and circular geometries of cup.

Indexed as

Contact stressCup inclinationElevated cupHip resurfacingMicroseparation

Identifiers

PMID38812869
PMCPMC11130114

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.