Three-dimensional sonography has satisfied accuracy for detecting rotator cuff tears.

Xin Wang, Wei Zhang, Jinlei Dong, Lianxin Li, Yuzhi Xiao, Fanxiao Liu

Abstract read
In one paragraph

Article in Frontiers in surgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Xin Wang *Department of Anesthesia Operating Room, Shandong Provincial Hospital Affiliated to Shandong First Medical University, Jinan, Shandong, China.
Wei Zhang *Department of Orthopaedics, Shandong Provincial Hospital Affiliated to Shandong First Medical University, Jinan, Shandong, China.
Jinlei DongDepartment of Orthopaedics, Shandong Provincial Hospital Affiliated to Shandong First Medical University, Jinan, Shandong, China.
Lianxin LiDepartment of Orthopaedics, Shandong Provincial Hospital Affiliated to Shandong First Medical University, Jinan, Shandong, China.
Yuzhi XiaoDepartment of Orthopaedics, Shandong Provincial Hospital Affiliated to Shandong First Medical University, Jinan, Shandong, China.
Fanxiao LiuDepartment of Orthopaedics, Shandong Provincial Hospital Affiliated to Shandong First Medical University, Jinan, Shandong, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Rotator cuff injuries and tears are common causes of shoulder pain and dysfunction, necessitating accurate diagnostic methods to guide clinical decision-making. This study evaluates the diagnostic utility of three-dimensional (3D) shoulder sonography in identifying rotator cuff injury and tear patterns. Methods: A comprehensive search across seven electronic databases, which included Cochrane Library, Embase, PubMed, Cochrane Library, China Biology Medicine (CBM) database, CNKI, Wanfang, and VIP database. These databases were utilized to retrieve articles that assess the diagnostic value of 3D shoulder sonography for identifying rotator cuff injuries and tear patterns. The effectiveness of 3D shoulder sonography was assessed in terms of sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), and diagnostic odds ratio (DOR). For each parameter, the 95% confidence intervals were calculated. Additionally, summary receiver operating characteristic curves (SROCs) were constructed, allowing for a comprehensive evaluation of diagnostic accuracy, which is reflected in the area under the SROC curve (AUC). Results: Screening of 8,508 identified nine literatures eligible for inclusion in the meta-analysis, encompassing a total of 366 patients. The analysis of detecting any rotator cuff tear revealed a sensitivity of 0.97 and specificity of 0.87, yielding a DOR of 90.03 and an AUC of 0.98. Furthermore, 3D shoulder sonography demonstrated satisfactory accuracy in detecting both full and partial-thickness rotator cuff tears (Sensitivity: 0.92 vs. 0.83, specificity: 0.94 vs. 097, and AUC: 0.96 vs. 0.95). Conclusion: This study indicates that three-dimensional sonography has satisfied accuracy for detecting rotator cuff tears.

Indexed as

3Ddiagnostic studyrotator cuff tearsshoulder painsonographytear pattern