ArticleDigestive diseases and sciences2024
A Comprehensive Analysis of Reported Adverse Events and Device Failures Associated with Esophageal Self-Expandable Metal Stents: An FDA MAUDE Database Study.
Article in Digestive diseases and sciences, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed.
- A Soft-Robotic Biomimetic Benchtop Model for Esophageal Motility Simulation.Nature communications · 2026Article
- Article
- Endoscopic incisional balloon dilation combined with anti-scarring agents for postoperative esophageal anastomotic strictures.DEN open · 2025Article
- An Analysis of the Food and Drug Administration Manufacturer and User Facility Device Experience Database for MAGnetic Expansion Control Spinal Rods.Therapeutic innovation & regulatory science · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
13 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
introductionEsophageal Stents are used to maintain esophageal lumen patency in esophageal strictures caused by intrinsic and/or extrinsic malignancies and the occlusion of concomitant esophageal fistulas. While data on the efficacy and safety of esophageal stents exist, comprehensive evaluation of adverse events is limited. The aim of this study is to investigate the reported adverse events and device failures associated with esophageal self-expandable metal stents (SEMS) using the FDA's Manufacturer and User Facility Device Experience (MAUDE) database.
methodsPost-marketing surveillance data for the esophageal SEMSs were analyzed using the FDA's MAUDE database from January 2014 to December 10, 2023. The outcomes of interest were patient-related adverse events and device failures. Statistical analysis was performed using Microsoft Excel 2010 and SPSS. Pooled numbers and percentages were calculated for each adverse event. Continuous variables underwent analysis using a two-tailed student t test, and significance was set to p ≤ 0.05.
resultsDuring the study period, 548 MAUDE reports revealed 873 device failures and 186 patient-related adverse events. The most common device issues were stent activation, positioning, or separation problems (4 n = 403; 46.2%), followed by device detachment or migration (n = 109, 12.5%), and material problems (n = 93, 10.7%). Patient complications included dysphagia/odynophagia (10%), perforation, pain, and bleeding (each 7.6%). The most common device failures in over-the-wire (OTW) stents and through-the-scope (TTS) stents were activation, positioning, or separation problems (TTS: n = 183, 52.6% vs OTW: n = 220, 41.9%). Compared to OTW stents, TTS stents had higher migration and breakage (13.5% vs. 11.8%, p = 0.24), and (9.2% vs. 6.7%, p = 0.08) respectively, while OTW stents had more challenges with stent advancement or removal (5.1% vs. 0.3%, p < 0.001 and 4.6% vs 3.4%, p = 0.19, respectively) and material problems (14.7% vs. 4.6%, p < 0.001). Activation, positioning, and separation problems were the most frequent device failures in fully covered (FC) and partially covered (PC) stents (FC: n = 62, 32.8%, PC: n = 168, 43.5%). FC stents had higher migration rates (20.6% vs 9.8%, p < 0.001), while PC stents exhibited more material problems (17.4% vs. 5.8%, p < 0.001) and difficulties with advancing the stents (6.7% vs. 0%, p < 0.001).
conclusionOur examination showed a prevalence of reported device complications associated with stent activation, positioning, and separation problems. Dysphagia or odynophagia emerged as the most frequently reported patient complication. Furthermore, our analysis, provides insights into TTS vs. OTW and FC vs. PC esophageal SEMSs, enabling endoscopists and manufacturers to better understand adverse events and potentially optimize device design for future iterations.
Indexed as
Identifiers
38811504What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.