Evidence map›Paper›PMID 38811484›Full record

ArticleInternational journal of computer assisted radiology and surgery2024

Micro-robotic percutaneous targeting of type II endoleaks in the angio-suite.

Gerlig Widmann, Johannes Deeg, Andreas Frech, Josef Klocker, Gudrun Feuchtner, Martin Freund

Erratum issuedAbstract read
In one paragraph

Article in International journal of computer assisted radiology and surgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 1 paper, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

6 authors.

Gerlig WidmannDepartment of Radiology, Medical University of Innsbruck, Anichstr. 35, 6020, Innsbruck, Austria. gerlig.widmann@i-med.ac.at.ORCID http://orcid.org/0000-0002-7255-0672
Johannes DeegDepartment of Radiology, Medical University of Innsbruck, Anichstr. 35, 6020, Innsbruck, Austria.
Andreas FrechDepartment of Vascular Surgery, Medical University of Innsbruck, Innsbruck, Austria.
Josef KlockerDepartment of Vascular Surgery, Medical University of Innsbruck, Innsbruck, Austria.
Gudrun FeuchtnerDepartment of Radiology, Medical University of Innsbruck, Anichstr. 35, 6020, Innsbruck, Austria.
Martin FreundDepartment of Radiology, Medical University of Innsbruck, Anichstr. 35, 6020, Innsbruck, Austria.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeEndovascular aneurysm repair has emerged as the standard therapy for abdominal aortic aneurysms. In 9-30% of cases, retrograde filling of the aneurysm sac through patent branch arteries may result in persistence of blood flow outside the graft and within the aneurysm sac. This condition is called an endoleak type II, which may be treated by catheter-based embolization in case of continued sac enlargement. If an endovascular access is not possible, percutaneous targeting of the perfused nidus remains the only option. However, this can be very challenging due to the difficult access and deep puncture with risk of organ perforation and bleeding. Innovative targeting techniques such as robotics may provide a promising option for safe and successful targeting.

methodsIn nine consecutive patients, percutaneous embolization of type II endoleaks was performed using a table-mounted micro-robotic targeting platform. The needle path from the skin entry to the perfused nidus was planned based on the C-arm CT image data in the angio-suite. Entry point and path angle were aligned using the joystick-operated micro-robotic system under fluoroscopic control, and the coaxial needle was introduced until the target point within the perfused nidus was reached.

resultsAll punctures were successful, and there were no puncture-related complications. The pre-operative C-arm CT was executed in 11-15 s, and pathway planning required 2-3 min. The robotic setup and sterile draping were performed in 1-2 min, and the alignment to the surgical plan took no longer than 30 s.

conclusionDue to the small size, the micro-robotic platform seamlessly integrated into the routine clinical workflow in the angio-suite. It offered significant benefits to the planning and safe execution of double-angulated deeply localized targets, such as type II endoleaks.

Indexed as

Aortic Aneurysm, AbdominalEmbolization, TherapeuticEndoleakAgedAged, 80 and overEndovascular ProceduresFemaleHumansMaleRoboticsRobotic Surgical ProceduresTomography, X-Ray ComputedTreatment OutcomeAbdominal aortic aneurysmAccuracyAngiographyEndoleakInterventional radiologyNavigationRobotics

Identifiers

PMID38811484
PMCPMC11329533

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.