Evidence map›Paper›PMID 38810138›Full record

ArticleDento maxillo facial radiology2024

The influence of different cheek and lip retractors and emissivity on intraoral infrared thermography.

Layrlla Kateriny Moura Oliveira Lopes, Rodolfo Ramos Castelo Branco, Rafaela Pequeno Reis Sousa, Elisa Diniz de Lima, Diego Filipe Bezerra Silva, Daniela Pita de Melo

Abstract read
In one paragraph

Article in Dento maxillo facial radiology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Layrlla Kateriny Moura Oliveira LopesDepartment of Dentistry, State University of Paraíba, Campina Grande 58429-500, Brazil.ORCID 0000-0002-7209-9930
Rodolfo Ramos Castelo BrancoCenter for Strategic Technologies in Health, State University of Paraíba, Campina Grande 58429-500, Brazil.ORCID 0000-0003-4805-9135
Rafaela Pequeno Reis SousaDepartment of Dentistry, State University of Paraíba, Campina Grande 58429-500, Brazil.ORCID 0000-0001-6446-3539
Elisa Diniz de LimaDepartment of Dentistry, State University of Paraíba, Campina Grande 58429-500, Brazil.ORCID 0000-0003-2840-7825
Diego Filipe Bezerra SilvaDepartment of Dentistry, State University of Paraíba, Campina Grande 58429-500, Brazil.ORCID 0000-0002-6721-0745
Daniela Pita de MeloCollege of Dentistry, University of Saskatchewan, Saskatoon S7N 5E5, Canada.ORCID 0000-0002-6477-6997

Funding

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior-Brasil
6 · The paper itself

Abstract

objectivesTo assess the influence of two conventional and one adapted cheek and lip retractors and three emissivity setting values on intraoral infrared thermography (IT) temperature values.

methodsThe sample was composed by 50 volunteers. Three cheek and lip retractors were tested: Group 1-flex retractor (FR); Group 2-FR adapted with Styrofoam; Group 3-U-type retractor (UR) for cheek and lip. All thermograms were acquired using FLIR T650 infrared camera. A set of three thermograms in frontal norm were acquired for each lip and cheek retractor at 0.91, 0.96, and 0.98ε, with an interval of 15 min between each set of images to avoid thermal interference. All images were assessed by two observers. The ROIs' mean temperature of the four upper incisors was recorded. Two-way ANOVA and Sidak post-test were used for data assessment with a significance level of 5%.

resultsGroup 3 showed higher mean temperature than Groups 1 and 2 at all emissivity settings for all assessed teeth (P < .05). 0.91ε showed higher temperature than 0.96ε and 0.98ε for all assessed variables (P < .01). Contralateral teeth assessed using Group 3 at 0.91ε showed statistical differences between each other (P < .05). No statistical difference was observed between contralateral teeth assessed using Groups 1 and 2 at 0.96ε and 0.98ε (P > .05).

conclusionsThe choice of cheek and lip retractor and emissivity setting can interfere on intraoral IT temperature values. U-type cheek and lip retractor and 0.91ε setting should not be used for IT image acquisition when assessing dental tissues.

Indexed as

CheekInfrared RaysLipThermographyAdultEquipment DesignFemaleHumansMaleYoung Adultmouth mucosatemperaturethermographytooth

Identifiers

PMID38810138
PMCPMC11358626

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.