Evidence map›Paper›PMID 38809953›Full record

ArticlePloS one2024

Enhancing healthcare IoT systems for diabetic patient monitoring: Integration of Harris Hawks and grasshopper optimization algorithms.

Mehdi Hosseinzadeh, Zohre Arabi, Saqib Ali, Hong Min, Mazhar Hussain Malik

Abstract read
In one paragraph

Article in PloS one, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Mehdi HosseinzadehInstitute of Research and Development, Duy Tan University, Da Nang, Vietnam.
Zohre ArabiComputer Engineering and Information Technology Department, Payam Noor University, Tehran, Iran.
Saqib AliDepartment of Information Systems, College of Economics and Political Science, Sultan Qaboos University, Al Khoudh, Muscat, Oman.
Hong MinSchool of Computing, Gachon University, Seongnam, Republic of Korea.ORCID 0000-0002-9099-0890
Mazhar Hussain MalikSchool of Computer Science and Creative Technologies College of Arts, Technology and Environment (CATE) University of the West of England Frenchay Campus, Stoke Gifford, United Kingdom.ORCID 0000-0001-8890-1310

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The integration of the Internet of Things (IoT) in healthcare, especially for people with diabetes, allows for constant health monitoring. This means that doctors can watch over patients' health more closely, making sure they catch any issues early on. With this technology, healthcare workers can be more accurate and effective when keeping an eye on how patients are doing. This not only helps in keeping track of patients' health in real-time but also makes the whole process more reliable and efficient.By implementing appropriate routing techniques, the transmission of diabetic patients' data to medical centers will facilitate real-time and timely responses from healthcare professionals. The grasshopper optimization algorithm is employed in the proposed approach to cluster network nodes, resulting in the formation of a network tree that facilitates the establishment of connections between the cluster head and the base station. After identifying the cluster head and establishing the clusters, the second stage of routing is implemented by employing the Harris Hawks optimization algorithm. This algorithm ensures that the data pertaining to diabetic patients is transmitted to the treatment centers and hospitals with minimal delay. For node routing, the optimal next step is selected based on the parameters such as the residual energy of the node, the ratio of delivered data packages, and the number of the neighbors of the node. To continue, first, the MATLAB software is utilized to simulate the proposed method, and then, it is compared with other similar methods. This comparison is conducted based on various parameters, including delay, energy consumption, network throughput, and network lifespan. Compared to other methods, the proposed method demonstrates a significant 33% improvement in the average point-to-point delay parameter in the subsequent iterations or rounds.

Indexed as

AlgorithmsDiabetes MellitusInternet of ThingsHumansMonitoring, Physiologic

Identifiers

PMID38809953
PMCPMC11135669

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.