Evidence map›Paper›PMID 38809423›Full record

ArticleEuropean journal of orthopaedic surgery & traumatology : orthopedie traumatologie2024

Biomechanical characteristics of the meniscocapsular junction of the posterior segment of the medial meniscus.

Quentin Nicolas, Ramy Samargandi, Sylvain Calloch, Frederic Dubrana, Francois-Xavier Gunepin, Remi Di Francia

Abstract read
PubMed Publisher
In one paragraph

Article in European journal of orthopaedic surgery & traumatology : orthopedie traumatologie, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Meniscal extrusion: Multiple theories, one clinical challenge.Journal of experimental orthopaedics · 2026
    Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Quentin NicolasOrthopedic Surgery Department, Tours Regional University Hospital, University of Tours - CHRU Trousseau Orthopedic Trauma Department, 1C, Avenue de la République, Chambray-les-Tours, 37170, Tours, France. qni.nicolas@gmail.com.
Ramy SamargandiOrthopedic Surgery Department, Tours Regional University Hospital, University of Tours - CHRU Trousseau Orthopedic Trauma Department, 1C, Avenue de la République, Chambray-les-Tours, 37170, Tours, France.
Sylvain CallochENSTA Bretagne, UMR CNRS 6027, IRDL, Brest, France.
Frederic DubranaFaculty of Medicine, University of Bretagne Occidentale, Brest, France.
Francois-Xavier GunepinOrthopedic Surgery, Clinique Mutualiste de la Porte de Lorient, Lorient, France.
Remi Di FranciaFaculty of Medicine, University of Bretagne Occidentale, Brest, France.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeDespite extensive literature available on the mechanical properties of knee ligaments and menisci, research on the mechanical properties of the meniscus-capsular junction (MCJ) is lacking. This study aims to investigate the biomechanical behavior of the MCJ of the medial meniscus using a tensile failure test. MATERIALS AND

methodsSeven dissected cadaveric knees were used for biomechanical analysis. Tensile failure tests were performed using an INSTRON ElectroPuls E1000 stress system to measure stress/strain curves, maximum load at failure, elastic limit load, elongation at break, elongation at the elastic limit, and linear stiffness, were collected and analyzed.

resultsAll ruptures occurred at the MCJ. The MCJ displayed similar mechanical properties to knee ligaments. Average values were: maximum load at failure (63.9 ± 3.2 N), yield load (52.9 N ± 2.6 N), elongation at break (2.5 mm ± 0.3 mm), elongation at the elastic limit (1.25 mm ± 0.15 mm), strain at break (47.0% ± 3.5%), strain at yield (23.2% ± 2.3%), and stiffness (56.6 ± 9. N/mm

conclusionThe meniscus-capsular junction's mechanical properties are similar to other knee ligaments and may play a role in knee stability. The findings provide insights into the the behavior of the meniscus-capsular junction could have clinical implications for diagnosing and surgical treatment of meniscocapsular lesions.

Indexed as

CadaverMenisci, TibialAgedBiomechanical PhenomenaFemaleHumansKnee JointLigaments, ArticularMaleMiddle AgedStress, MechanicalTensile StrengthArthroscoyBiomechanical studyHidden lesionMedial meniscusMeniscocapsularRamp lesion

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.