Development of a continuum manipulator with variable bending length and piecewise stiffness for transoral laryngeal surgery.

Wentuo Yang, Yongfeng Cao, Shuang Wang, Zefeng Liu, Hongyu Cheng, Le Xie

Abstract read
PubMed Publisher
In one paragraph

Article in International journal of computer assisted radiology and surgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Wentuo YangInstitute of Forming Technology & Equipment, Shanghai Jiao Tong University, Shanghai, 200030, China.ORCID http://orcid.org/0000-0002-1991-5214
Yongfeng CaoInstitute of Forming Technology & Equipment, Shanghai Jiao Tong University, Shanghai, 200030, China.
Shuang WangInstitute of Forming Technology & Equipment, Shanghai Jiao Tong University, Shanghai, 200030, China.
Zefeng LiuInstitute of Forming Technology & Equipment, Shanghai Jiao Tong University, Shanghai, 200030, China.
Hongyu ChengInstitute of Forming Technology & Equipment, Shanghai Jiao Tong University, Shanghai, 200030, China.
Le XieInstitute of Forming Technology & Equipment, Shanghai Jiao Tong University, Shanghai, 200030, China. lexie@sjtu.edu.cn.

Funding

Fujian Provincial Department of Science and Technology 2022High Level Innovation and Entrepreneurial Research Team Program in Jiangsu 2021C003RNational Natural Science Foundation of China 61973211National Natural Science Foundation of China 62133009National Natural Science Foundation of China 62211540723Science and Technology Commission of Shanghai Municipality 21550714200
6 · The paper itself

Abstract

purposeContinuum manipulators (CMs) show great potential in transoral laryngeal surgery due to their flexibility. However, CMs for transoral surgery face several issues: large size, which reduces practicality; intersegment coupling, which causes undesired deflection; and a lack of versatility that limits their applicability across different patient groups.

methodsThis work combines a rod-driven proximal segment and a cable-driven distal segment to achieve piecewise stiffness, alleviating the issue of intersegment coupling. A rigid constraint tube is integrated into the proximal segment to diversify its bending behavior. Preliminary experiments are conducted to validate the design concept.

resultsThe proposed CM has an overall diameter of only 6.5 mm. The proximal segment can achieve a 90° bending with various curvatures. At the working configuration, the coupling error between the proximal segment and the distal segment is less than 1 mm. The effectiveness of the proposed CM is successfully validated using a human model.

conclusionThe proposed continuum manipulator possesses the desirable characteristics of small size, low coupling, and high versatility, indicating its great potentialities for the diagnosis and treatment of laryngeal lesion.