Evidence map›Paper›PMID 38808133›Full record

ArticleFrontiers in medicine2024

T-shaped pars plana scleral incision to remove large intraocular foreign body.

Mario Damiano Toro, Katarzyna Nowomiejska, Marina Concilio, Lorenzo Motta, Krzysztof Marek Rekas, Ciro Costagliola, Teresio Avitabile, Niccolò Castellino, Georges Caputo, Tomasz Choragiewicz and 1 more

Abstract read
In one paragraph

Article in Frontiers in medicine, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Mario Damiano ToroEye Clinic, Public Health Department, University of Naples Federico II, Naples, Italy.
Katarzyna NowomiejskaDepartment of General and Pediatric Ophthalmology, Medical University of Lublin, Lublin, Poland.
Marina ConcilioDepartment of Medicine and Health Sciences "V. Tiberio", University of Molise, Campobasso, Italy.
Lorenzo MottaDepartment of Ophthalmology, William Harvey Hospital, East Kent Hospitals University NHS Foundation Trust, Ashford, United Kingdom.
Krzysztof Marek RekasStudents' Scientific Association at the Chair and Department of General and Pediatric Ophthalmology, Medical University of Lublin, Lublin, Poland.
Ciro CostagliolaEye Clinic, Department of Neuroscience, Reproductive Sciences and Dentistry, University of Naples Federico II, Naples, Italy.
Teresio AvitabileDepartment of Ophthalmology, University of Catania, Catania, Italy.
Niccolò CastellinoDepartment of Ophthalmology, University of Catania, Catania, Italy.
Georges CaputoDepartment of Pediatric Ophthalmology, Rothschild Foundation Hospital, Paris-Cedex, France.
Tomasz Choragiewicz *Department of General and Pediatric Ophthalmology, Medical University of Lublin, Lublin, Poland.
Robert Rejdak *Chair and Department of General and Pediatric Ophthalmology, Medical University of Lublin, Lublin, Poland.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Aim: To investigate the efficacy and safety profile of T-shaped pars plana scleral incision technique in removing large intraocular foreign bodies, during 23-gauge pars plana vitrectomy. Methods: Retrospective interventional case series that included patients diagnosed with a large intraocular foreign body (IOFB). Possible postoperative complications were recorded 24 h, 1 month, 3 and 6 months postoperatively. Results: Thirty eyes of 30 patients (48 ± 5 years old) were enrolled. All IOFBs were successfully removed: mean diameters of 7.8 ± 2.0 mm and 2.6 ± 0.3 mm. Silicone oil and sulfur hexafluoride were used in 27 and 3 eyes, respectively. Lensectomy was performed in 27 eyes. Intraocular lens was implanted at first attempt in 12 eyes; during a second operation in 12 eyes and 6 eyes remained aphakic. At any follow-up, no signs of postoperative complications were observed. Secondary retinal detachment occurred in 12 eyes. Mean preoperative corrected distance visual acuity was 0.04, on the Snellen scale; it increased to 0.07, at last follow-up. Mean intraocular pressure was 17.97 mmHg. All eyes were preserved. Conclusion: T-shaped scleral incision could be an effective, safe and easy-to-perform standard procedure to remove large IOFBs during pars plana vitrectomy, without increasing the risk of surgical complications and additional damage to the ocular tissues.

Indexed as

intraocular foreign bodyocular traumapars plana vitrectomyscleral woundsurgical techinque

Identifiers

PMID38808133
PMCPMC11130438

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.