Evidence map›Paper›PMID 38807861›Full record

ArticleTransplantation direct2024

Subnormothermic Oxygenated Machine Perfusion (24 h) in DCD Kidney Transplantation.

Nader Abraham, Qimeng Gao, Riley Kahan, Isaac S Alderete, Bangchen Wang, David N Howell, Imran J Anwar, Joseph M Ladowski, Kentaro Nakata, Ethan Jarrett and 9 more

Abstract read
In one paragraph

Article in Transplantation direct, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Article
  2. Review
  3. Review
  4. Article
  5. Article
  6. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

19 authors.

Nader AbrahamDepartment of Surgery, Duke University, Duke Ex-Vivo Organ Lab (DEVOL), Durham, NC.
Qimeng GaoDepartment of Surgery, Duke University, Duke Ex-Vivo Organ Lab (DEVOL), Durham, NC.ORCID https://orcid.org/0000-0002-2456-7672
Riley KahanDepartment of Surgery, Duke University, Duke Ex-Vivo Organ Lab (DEVOL), Durham, NC.
Isaac S AldereteDepartment of Surgery, Duke University, Duke Ex-Vivo Organ Lab (DEVOL), Durham, NC.
Bangchen WangDepartment of Pathology, Duke University, Durham, NC.ORCID https://orcid.org/0000-0002-0942-7858
David N HowellDepartment of Pathology, Duke University, Durham, NC.
Imran J AnwarDepartment of Surgery, Duke University, Duke Ex-Vivo Organ Lab (DEVOL), Durham, NC.
Joseph M LadowskiDepartment of Surgery, Duke University, Duke Ex-Vivo Organ Lab (DEVOL), Durham, NC.
Kentaro NakataDepartment of Surgery, Duke University, Duke Ex-Vivo Organ Lab (DEVOL), Durham, NC.
Ethan JarrettBMI OrganBank (BMI), Winston Salem, NC.
Kendall HlewickiBMI OrganBank (BMI), Winston Salem, NC.
Greta CywinskaDepartment of Surgery, Duke University, Duke Ex-Vivo Organ Lab (DEVOL), Durham, NC.
Ryan NeillDepartment of Surgery, Duke University, Duke Ex-Vivo Organ Lab (DEVOL), Durham, NC.
Charles AardemaBMI OrganBank (BMI), Winston Salem, NC.
David A GerberDepartment of Surgery, University of North Carolina, Chapel Hill, NC.
Prabir Roy-ChaudhuryDepartment of Medicine, University of North Carolina, Chapel Hill, NC.
Benjamin A HughesDepartment of Surgery, Duke University, Duke Ex-Vivo Organ Lab (DEVOL), Durham, NC.
Matthew G HartwigDepartment of Surgery, Duke University, Duke Ex-Vivo Organ Lab (DEVOL), Durham, NC.ORCID https://orcid.org/0000-0001-8393-2791
Andrew S BarbasDepartment of Surgery, Duke University, Duke Ex-Vivo Organ Lab (DEVOL), Durham, NC.ORCID https://orcid.org/0000-0003-3476-2313

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Ex vivo kidney perfusion is an evolving platform that demonstrates promise in preserving and rehabilitating the kidney grafts. Despite this, there is little consensus on the optimal perfusion conditions. Hypothermic perfusion offers limited functional assessment, whereas normothermic perfusion requires a more complex mechanical system and perfusate. Subnormothermic machine perfusion (SNMP) has the potential to combine the advantages of both approaches but has undergone limited investigation. Therefore, the present study sought to determine the suitability of SNMP for extended kidney preservation. Methods: SNMP at 22-25 °C was performed on a portable device for 24 h with porcine kidneys. Graft assessment included measurement of mechanical parameters and biochemical analysis of the perfusate using point-of-care tests. To investigate the viability of kidneys preserved by SNMP, porcine kidney autotransplants were performed in a donation after Results: In the perfusion-only cohort, porcine kidneys all displayed successful perfusion for 24 h by SNMP, evidenced by stable mechanical parameters and biological markers of graft function. Furthermore, in the transplant cohort, DCD grafts with 30 min of warm ischemic injury demonstrated superior posttransplant graft function when preserved by SNMP in comparison with SCS. Finally, human kidneys that underwent 24-h perfusion exhibited stable functional and biological parameters consistent with observations in porcine organs. Conclusions: These observations demonstrate the suitability and cross-species generalizability of subnormothermic machine perfusion to maintain stable kidney perfusion and provide foundational evidence for improved posttransplant graft function of DCD kidneys after SNMP compared with SCS.

Identifiers

PMID38807861
PMCPMC11132391

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.