Evidence map›Paper›PMID 38807292›Full record

ArticleJournal of applied clinical medical physics2024

Enhancing diagnostic performance and image quality in coronary CT angiography: Impact of SnapShot Freeze 2 algorithm across varied heart rates in stent patients.

Zhehao Wu, Qijia Han, Yuying Liang, Zhijuan Zheng, Minyi Wu, Zhu Ai, Kun Ma, Zhiming Xiang

Abstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Zhehao WuPostgraduate Cultivation Base of Guangzhou University of Chinese Medicine, Panyu Central Hospital, Guangzhou, China.
Qijia HanDepartment of Radiology, Guangzhou Panyu Central Hospital, Guangzhou, China.
Yuying LiangDepartment of Radiology, Guangzhou Panyu Central Hospital, Guangzhou, China.
Zhijuan ZhengPostgraduate Cultivation Base of Guangzhou University of Chinese Medicine, Panyu Central Hospital, Guangzhou, China.
Minyi WuDepartment of Radiology, Guangzhou Panyu Central Hospital, Guangzhou, China.
Zhu AiDepartment of Radiology, Guangzhou Panyu Central Hospital, Guangzhou, China.
Kun MaCT Imaging Research Center, GE HealthCare China, Guangzhou, China.
Zhiming XiangDepartment of Radiology, Guangzhou Panyu Central Hospital, Guangzhou, China.

Funding

National Natural Science Foundation of China 82171931Panyu Science and Technology Program of Guangzhou 2020-Z04-020Panyu Science and Technology Program of Guangzhou 2020-Z04-055Science and Technology Program of Guangzhou 202102080572
6 · The paper itself

Abstract

purposeTo investigate the enhancement of image quality achieved through the utilization of SnapShot Freeze 2 (SSF2), a comparison was made against the results obtained from the original SnapShot Freeze algorithm (SSF) and standard motion correction (STND) in stent patients undergoing coronary CT angiography (CCTA) across the entire range of heart rates. MATERIALS AND

methodsA total of 118 patients who underwent CCTA, were retrospectively included in this study. Images of these patients were reconstructed using three different algorithms: SSF2, SSF, and STND. Objective assessments include signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), diameters of stents and artifact index (AI). The image quality was subjectively evaluated by two readers.

resultsCompared with SSF and STND, SSF2 had similar or even higher quality in the parameters (AI, SNR, CNR, inner diameters) of coronary artery, stent, myocardium, MV (mitral valve), TV (tricuspid valve), AV (aorta valve), and PV (pulmonary valve), and aortic root (AO). Besides the above structures, SSF2 also demonstrated comparable or even higher subjective scores in atrial septum (AS), ventricular septum (VS), and pulmonary artery root (PA). Furthermore, the enhancement in image quality with SSF2 was significantly greater in the high heart rate group compared to the low heart rate group. Moreover, the improvement in both high and low heart rate groups was better in the SSF2 group compared to the SSF and STND group. Besides, when using the three algorithms, an effect of heart rate variability on stent image quality was not detected.

conclusionCompared to SSF and STND, SSF2 can enhance the image quality of whole-heart structures and mitigate artifacts of coronary stents. Furthermore, SSF2 has demonstrated a significant improvement in the image quality for patients with a heart rate equal to or higher than 85 bpm.

Indexed as

AlgorithmsComputed Tomography AngiographyCoronary AngiographyHeart RateImage Processing, Computer-AssistedSignal-To-Noise RatioStentsAdultAgedArtifactsCoronary VesselsFemaleHumansMaleMiddle AgedRadiographic Image Interpretation, Computer-Assistedcomputed tomographycoronary artery stentmotion correction

Identifiers

PMID38807292
PMCPMC11302822

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.