Evidence map›Paper›PMID 38804351›Full record

ArticleVision (Basel, Switzerland)2024

A Morphometric Study of the Pars Plana of the Ciliary Body in Human Cadaver Eyes.

Jaime Guedes, Bruno F Fernandes, Denisse J Mora-Paez, Rodrigo Brazuna, Alexandre Batista da Costa Neto, Dillan Cunha Amaral, Adriano Cypriano Faneli, Ricardo Danilo Chagas Oliveira, Adroaldo de Alencar Costa Filho, Adalmir Morterá Dantas

Abstract read
In one paragraph

Article in Vision (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Jaime GuedesDepartment of Ophthalmology, Federal University of Rio de Janeiro, Rio de Janeiro 21941-971, RJ, Brazil.
Bruno F FernandesArgumento Institute, Boucherville, QC J4B-2G6, Canada.ORCID 0000-0002-5385-3571
Denisse J Mora-PaezGlaucoma Research Center, Wills Eye Hospital, Philadelphia, PA 19107, USA.
Rodrigo BrazunaDepartment of Ophthalmology, Federal University of the State of Rio de Janeiro, Rio de Janeiro 22290-240, RJ, Brazil.
Alexandre Batista da Costa NetoDepartment of Ophthalmology, Federal University of the State of Rio de Janeiro, Rio de Janeiro 22290-240, RJ, Brazil.ORCID 0000-0001-6233-096X
Dillan Cunha AmaralDepartment of Ophthalmology, Federal University of Rio de Janeiro, Rio de Janeiro 21941-971, RJ, Brazil.ORCID 0009-0002-7948-154X
Adriano Cypriano FaneliBahiana School of Medicine and Public Health, Salvador 40290-000, BA, Brazil.ORCID 0000-0001-8834-2600
Ricardo Danilo Chagas OliveiraOphthalmology, Opty Group, Rio de Janeiro 22640-100, RJ, Brazil.
Adroaldo de Alencar Costa FilhoDepartment of Ophthalmology, Federal University of Rio de Janeiro, Rio de Janeiro 21941-971, RJ, Brazil.
Adalmir Morterá DantasDepartment of Ophthalmology, Federal University of Rio de Janeiro, Rio de Janeiro 21941-971, RJ, Brazil.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This study aimed to determine the pars plana length in postmortem human eyes using advanced morphometric techniques and correlate demographics to ocular metrics such as age, sex, ethnicity, and axial length. Between February and July 2005, we conducted a cross-sectional observational study on 46 human cadaver eyes deemed unsuitable for transplant by the SBO Eye Bank. The morphometric analysis was performed on projected images using a surgical microscope and a video-microscopy system with a 20.5:1 correction factor. The pars plana length was measured three times per quadrant, with the final value being the mean of these measurements. Of the 46 eyes collected, 9 were unsuitable for the study due to technical constraints in conducting intraocular measurements. Overall, the average axial length was 25.20 mm. The average pars plana length was 3.8 mm in all quadrants, with no measurements below 2.8 mm or above 4.9 mm. There were no statistically significant variations across quadrants or with age, sex, axial length, or laterality. Accurately defining the pars plana dimensions is crucial for safely accessing the posterior segment of the eye and minimizing complications during intraocular procedures, such as intravitreal injections and vitreoretinal surgeries.

Indexed as

anatomymorphometrypars plana

Identifiers

PMID38804351
PMCPMC11130848

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.