Evidence map›Paper›PMID 38803937›Full record

ArticleHeliyon2024

Novel ultrasensitive automated kinetic exclusion assay for measurement of plasma levels of soluble PD-L1, the predictive and prognostic biomarker in cancer patients treated with immune checkpoint inhibitors.

Ibrahim A Darwish, Waleed Alahmad, Rajendran Vinoth

Abstract read
In one paragraph

Article in Heliyon, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. [Enhanced tumoricidal activity of PD-1 antibody-secreting c-Met CAR-T cells against pancreatic cancer cells].Nan fang yi ke da xue xue bao = Journal of Southern Medical University · 2024
    Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Ibrahim A DarwishDepartment of Pharmaceutical Chemistry, College of Pharmacy, King Saud University, P.O. Box 2457, Riyadh, 11451, Saudi Arabia.
Waleed AlahmadDepartment of Chemistry, Faculty of Science, Chulalongkorn University, Bangkok, 10330, Thailand.
Rajendran VinothElectrodics and Electrocatalysis Division, CSIR-Central Electrochemical Research Institute (CECRI), Karaikudi, Tamil Nadu, 630003, India.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Recently, the blood plasma or serum levels of soluble programmed death protein 1 (PD-L1), but not tissue PD-L1 expression level, have been proposed as an effective predictive and prognostic biomarker in patients treated with immune checkpoint inhibitors for different types of cancers. The quantification of soluble PD-L1 in blood will provide a quick evaluation of patients' immune status; however, the available assays have limitations in their sensitivity, reproducibility, and accuracy for use in clinical settings. To overcome these problems, this study was dedicated to developing an ultrasensitive automated flow-based kinetic exclusion assay (KinExA) for the accurate and precise measurement of soluble PD-L1 in plasma. The assay was developed with the assistance of KinExA™ 3200 biosensor. In this assay, PD-L1 in its calibrator or plasma sample solution was pre-equilibrated with anti-PD-L1 monoclonal antibody. The equilibrated mixture solution was then passed rapidly over PD-L1 protein that has been coated onto polymethylmethacrylate beads consolidated as a microcolumn in the observation cell of the KinExA™ biosensor. The free anti- PD-L1 antibody was bound to the immobilized PD-L1, however, the unbound molecules were removed from the beads microcolumn by flushing the system with phosphate-buffered saline. Fluorescein-labeled secondary antibody was passed rapidly over the beads, and the fluorescence signals were monitored during the flow of the labeled antibody through the beads. The calibration curve was generated by plotting the binding percentages as a function of PD-L1 concentrations in its sample solution. The working range of the assay with very a good correlation coefficient on a 4-parameter equation (r = 0.9992) was 0.5 - 100 pg mL

Indexed as

BiosensorCancerKinExAPD-L1Predictive and prognostic biomarkers

Identifiers

PMID38803937
PMCPMC11129001