ArticleHeliyon2024
Groove design optimization of femoral heads in solid hip implants: Study on stress distribution and total deformation using FEA and full factorial design.
Article in Heliyon, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Influence of Infill Density on the Fatigue Performance of FDM-Manufactured Orthopaedic Plates.Materials (Basel, Switzerland) · 2026Article
- Integrating finite element analysis in total hip arthroplasty for childhood hip disorders: Enhancing precision and outcomes.World journal of orthopedics · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Hip replacement surgery is a common procedure that relies on the implant's design to withstand daily activities. This study aims to investigate the impact of different surface groove designs on the performance of solid hip implants using finite element analysis (FEA) and optimization techniques. The study evaluates the influence of grooves on the stress distribution and total deformation of the implant, considering three designs: no grooves, horizontal grooves, and vertical grooves on the surface of the femoral head. The simulations were conducted using Ansys Mechanical, and the optimization process was carried out using the general full factorial design method in Minitab software. The results demonstrate that the groove design significantly affects the stress distribution and wear of the implant. The vertical groove design shows better overall results, indicating the best performance. The study also evaluated the influence of force on the performance of the implant, with different load range. The optimization process using the general full factorial design method revealed that the optimal groove design was a vertical model with an optimized groove depth and width. These findings offer valuable insights into the impact of surface groove designs on the performance of solid hip implants, leading to better patient outcomes and longer implant lifespan. Overall, this study provides a comprehensive understanding of the effect of surface groove design on the performance of solid hip implants.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.