ArticlePhysics and imaging in radiation oncology2024

Optimized raw data selection for artifact reduction of breathing controlled four-dimensional sequence scanning.

Juliane Szkitsak, Andre Karius, Susanne Fernolendt, Philipp Schubert, Stefan Speer, Rainer Fietkau, Christoph Bert, Christian Hofmann

Abstract read
In one paragraph

Article in Physics and imaging in radiation oncology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Juliane SzkitsakDepartment of Radiation Oncology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany.
Andre KariusDepartment of Radiation Oncology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany.
Susanne FernolendtSiemens Healthcare GmbH, 91301 Forchheim, Germany.
Philipp SchubertDepartment of Radiation Oncology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany.
Stefan SpeerDepartment of Radiation Oncology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany.
Rainer FietkauDepartment of Radiation Oncology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany.
Christoph BertDepartment of Radiation Oncology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany.
Christian HofmannDepartment of Radiation Oncology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background and purpose: Even with most breathing-controlled four-dimensional computed tomography (4DCT) algorithms image artifacts caused by single significant longer breathing still occur, resulting in negative consequences for radiotherapy. Our study presents first phantom examinations of a new optimized raw data selection and binning algorithm, aiming to improve image quality and geometric accuracy without additional dose exposure. Materials and methods: To validate the new approach, phantom measurements were performed to assess geometric accuracy (volume fidelity, root mean square error, Dice coefficient of volume overlap) for one- and three-dimensional tumor motion trajectories with and without considering motion hysteresis effects. Scans without significantly longer breathing cycles served as references. Results: Median volume deviations between optimized approach and reference of at maximum 1% were obtained considering all movements. In comparison, standard reconstruction yielded median deviations of 9%, 21% and 12% for one-dimensional, three-dimensional, and hysteresis motion, respectively. Measurements in one- and three-dimensional directions reached a median Dice coefficient of 0.970 ± 0.013 and 0.975 ± 0.012, respectively, but only 0.918 ± 0.075 for hysteresis motions averaged over all measurements for the optimized selection. However, for the standard reconstruction median Dice coefficients were 0.845 ± 0.200, 0.868 ± 0.205 and 0.915 ± 0.075 for one- and three-dimensional as well as hysteresis motions, respectively. Median root mean square errors for the optimized algorithm were 30 ± 16 HU Conclusions: The algorithm was proven to reduce 4DCT-related artifacts due to missing projection data without further dose exposure. An improvement in radiotherapy treatment planning due to better image quality can be expected.

Indexed as

4DCTArtifactsHysteresisIrregular breathingOptimized raw data selectionReconstruction

Identifiers

PMID38803466
PMCPMC11128500

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.