ArticleScientific reports2024
Design of the offline test electronics for the nozzle system of proton therapy.
Article in Scientific reports, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
11 authors.
Funding
Abstract
A set of nozzle equipment for proton therapy is currently under development at China Institute of Atomic Energy (CIAE). To facilitate the off-line commissioning of the whole equipment, a set of ionization chamber signal generation system, known as the test electronics, was designed. The results showed that the system can simulate the beam position, beam fluence (which exhibits a positive correlation with the dose), and other related analog signals generated by the proton beam when it traverses the ionization chamber. Moreover, the accuracy of the simulated beam position is within ± 0.33 mm, and the accuracy of the simulated beam fluence signal is within ± 1%. The test electronics can output analog signals representing environmental parameters. The test electronics meets the design requirements, which can be used for the commissioning of the nozzle system as well as the treatment control system without the presence of the proton beam.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.