ArticleTechniques in coloproctology2024
Validation of a 3D-printed model of cryptoglandular perianal fistulas.
Article in Techniques in coloproctology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed, 1 synthesis or guideline pooled it.
- The Current Applications in Surgery of Three-Dimensional Modelling Technology for Complex Fistula-In-Ano: A Systematic Review.ANZ journal of surgery · 2025Pooled it
- Evaluation of Reporting Methods for Assessment and Surgical Planning of Perianal Fistulas.Journal of imaging informatics in medicine · 2026Article
- Enhancing Patient Understanding of Perianal Fistula MRI Findings Using ChatGPT: A Randomized, Single Centre Study.Diagnostics (Basel, Switzerland) · 2025Article
- How to create a virtual and printed three-dimensional model of a complex fistula-in-ano.ANZ journal of surgery · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
introductionVisualising the course of a complex perianal fistula on imaging can be difficult. It has been postulated that three-dimensional (3D) models of perianal fistulas improve understanding of the perianal pathology, contribute to surgical decision-making and might even improve future outcomes of surgical treatment. The aim of the current study is to investigate the accuracy of 3D-printed models of perianal fistulas compared with magnetic resonance imaging (MRI).
methodsMRI scans of 15 patients with transsphincteric and intersphincteric fistulas were selected and then assessed by an experienced abdominal and colorectal radiologist. A standardised method of creating a 3D-printed anatomical model of cryptoglandular perianal fistula was developed by a technical medical physicist and a surgeon in training with special interest in 3D printing. Manual segmentation of the fistula and external sphincter was performed by a trained technical medical physicist. The anatomical models were 3D printed in a 1:1 ratio and assessed by two colorectal surgeons. The 3D-printed models were then scanned with a 3D scanner. Volume of the 3D-printed model was compared with manual segmentation. Inter-rater reliability statistics were calculated for consistency between the radiologist who assessed the MRI scans and the surgeons who assessed the 3D-printed models. The assessment of the MRI was considered the 'gold standard'. Agreement between the two surgeons who assessed the 3D printed models was also determined.
resultsConsistency between the radiologist and the surgeons was almost perfect for classification (κ = 0.87, κ = 0.87), substantial for complexity (κ = 0.73, κ = 0.74) and location of the internal orifice (κ = 0.73, κ = 0.73) and moderate for the percentage of involved external anal sphincter in transsphincteric fistulas (ICC 0.63, ICC 0.52). Agreement between the two surgeons was substantial for classification (κ = 0.73), complexity (κ = 0.74), location of the internal orifice (κ = 0.75) and percentage of involved external anal sphincter in transsphincteric fistulas (ICC 0.77).
conclusionsOur 3D-printed anatomical models of perianal fistulas are an accurate reflection of the MRI. Further research is needed to determine the added value of 3D-printed anatomical models in preoperative planning and education.
Indexed as
Identifiers
38801550What OpenQuestion holds
Registered trials