Evidence map›Paper›PMID 38800692›Full record

ArticleComputational and structural biotechnology journal2024

Contagious infection-free medical interaction system with machine vision controlled by remote hand gesture during an operation.

Van Doi Truong, Hyun-Kyo Lim, Seongje Kim, Than Trong Khanh Dat, Jonghun Yoon

Abstract read
In one paragraph

Article in Computational and structural biotechnology journal, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Van Doi TruongDepartment of Mechanical Design Engineering, Hanyang University, 222, Wangsimni-ro, Seongdongsu, Seoul 04763, Republic of Korea.
Hyun-Kyo LimDepartment of Mechanical Design Engineering, Hanyang University, 222, Wangsimni-ro, Seongdongsu, Seoul 04763, Republic of Korea.
Seongje KimDepartment of Mechanical Design Engineering, Hanyang University, 222, Wangsimni-ro, Seongdongsu, Seoul 04763, Republic of Korea.
Than Trong Khanh DatFaculty of Mechanical Engineering, Ho Chi Minh City University of Technology (HCMUT), 268 Ly Thuong Kiet Street, District 10, Ho Chi Minh City 700000, Viet Nam.
Jonghun YoonBK21 FOUR ERICA-ACE Center, Hanyang University, 55, Hanyangdaehak-ro, Sangnok-gu, Ansan-si, Gyeonggi-do 15588, Republic of Korea.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background and objective: Medical image visualization is a requirement in many types of surgery such as orthopaedic, spinal, thoracic procedures or tumour resection to eliminate risk such as "wrong level surgery". However, direct contact with physical devices such as mice or touch screens to control images is a challenge because of the potential risk of infection. To prevent the spread of infection in sterile environments, a contagious infection-free medical interaction system has been developed for manipulating medical images. Methods: We proposed an integrated system with three key modules: hand landmark detection, hand pointing, and hand gesture recognition. A proposed depth enhancement algorithm is combined with a deep learning hand landmark detector to generate hand landmarks. Based on the designed system, a proposed hand-pointing system combined with projection and ray-pointing techniques allows for reducing fatigue during manipulation. A proposed landmark geometry constraint algorithm and deep learning method were applied to detect six gestures including click, open, close, zoom, drag, and rotation. Additionally, a control menu was developed to effectively activate common functions. Results: The proposed hand-pointing system allowed for a large control range of up to 1200 mm in both vertical and horizontal direction. The proposed hand gesture recognition method showed high accuracy of over 97% and real-time response. Conclusion: This paper described the contagious infection-free medical interaction system that enables precise and effective manipulation of medical images within the large control range, while minimizing hand fatigue.

Indexed as

ContactlessGesture recognitionHuman-machine interactionPointing techniqueSterile environment

Identifiers

PMID38800692
PMCPMC11127465

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.