Evidence map›Paper›PMID 38799271›Full record

ArticleJournal of medical imaging (Bellingham, Wash.)2024

Low-contrast detectability of photon-counting-detector CT at different scan modes and image types in comparison with energy-integrating-detector CT.

Mingdong Fan, Zhongxing Zhou, Jarod Wellinghoff, Cynthia H McCollough, Lifeng Yu

Abstract read
In one paragraph

Article in Journal of medical imaging (Bellingham, Wash.), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Review
  2. Review
  3. Review
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Mingdong FanMayo Clinic, Department of Radiology, Rochester, Minnesota, United States.
Zhongxing ZhouMayo Clinic, Department of Radiology, Rochester, Minnesota, United States.ORCID https://orcid.org/0000-0003-1935-2762
Jarod WellinghoffMayo Clinic, Department of Radiology, Rochester, Minnesota, United States.
Cynthia H McColloughMayo Clinic, Department of Radiology, Rochester, Minnesota, United States.ORCID https://orcid.org/0000-0002-5346-332X
Lifeng YuMayo Clinic, Department of Radiology, Rochester, Minnesota, United States.ORCID https://orcid.org/0000-0002-4267-1326

Funding

Dissemination of a Software Platform for Efficient CT Radiation Dose Optimization and Diagnostic Performance AssessmentU24EB028936 · NIBIB · MAYO CLINIC ROCHESTER · PI YU, LIFENG · 2019 to 2023
$1.6M
NIBIB NIH HHS U24 EB028936
6 · The paper itself

Abstract

Purpose: We aim to compare the low-contrast detectability of a clinical whole-body photon-counting-detector (PCD)-CT at different scan modes and image types with an energy-integrating-detector (EID)-CT. Approach: We used a channelized Hotelling observer (CHO) previously optimized for quality control purposes. An American College of Radiology CT accreditation phantom was scanned on both PCD-CT and EID-CT with 10 phantom positionings. For PCD-CT, images were generated using two scan modes, standard resolution (SR) and ultra-high-resolution (UHR); two image types, virtual monochromatic images at 70 keV and low-energy threshold (T3D); both filtered-back-projection (FBP) and iterative reconstruction (IR) reconstruction methods; and three reconstruction kernels. For each positioning, three repeated scans were acquired for each scan mode, image type, and CTDIvol of 6, 12, and 24 mGy. For EID-CT, images acquired from scans (10 positionings × 3 repeats × 3 doses) were reconstructed using the closest counterpart FBP and IR kernels. CHO was applied to calculate the index of detectability ( Results: With the smooth Br44 kernel, the Conclusions: The comparison between PCD-CT and EID-CT was significantly influenced by the reconstruction method and kernel. With a smooth kernel that is typically used in low-contrast detection tasks, the PCD-CT demonstrated low-contrast detectability that was comparable to EID-CT with IR and showed no superiority when using FBP. With the use of sharper kernels, the PCD-CT significantly outperformed EID-CT in low-contrast detectability.

Indexed as

computed tomographyCTimage qualitymodel observerphoton-counting-detector CTquality controlradiation dose

Identifiers

PMID38799271
PMCPMC11116128

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.