Evidence map›Paper›PMID 38799270›Full record

ArticleJournal of medical imaging (Bellingham, Wash.)2024

Improved noise reduction in photon-counting detector CT using prior knowledge-aware iterative denoising neural network.

Shaojie Chang, Jeffrey F Marsh, Emily K Koons, Hao Gong, Cynthia H McCollough, Shuai Leng

Abstract read
In one paragraph

Article in Journal of medical imaging (Bellingham, Wash.), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Shaojie ChangMayo Clinic, Department of Radiology, Rochester, Minnesota, United States.ORCID https://orcid.org/0000-0003-0550-9650
Jeffrey F MarshMayo Clinic, Department of Radiology, Rochester, Minnesota, United States.
Emily K KoonsMayo Clinic, Department of Radiology, Rochester, Minnesota, United States.
Hao GongMayo Clinic, Department of Radiology, Rochester, Minnesota, United States.
Cynthia H McColloughMayo Clinic, Department of Radiology, Rochester, Minnesota, United States.ORCID https://orcid.org/0000-0002-5346-332X
Shuai LengMayo Clinic, Department of Radiology, Rochester, Minnesota, United States.ORCID https://orcid.org/0000-0002-6453-9481

Funding

Comprehensive characterization of coronary atherosclerotic disease using photon-counting-detector dual-source CT and its impact on patient managementR01EB028590 · NIBIB · MAYO CLINIC ROCHESTER · PI LENG, SHUAI, MCCOLLOUGH, CYNTHIA H · 2020 to 2023
$2.6M
NIBIB NIH HHS R01 EB028590
6 · The paper itself

Abstract

Purpose: We aim to reduce image noise in high-resolution (HR) virtual monoenergetic images (VMIs) from photon-counting detector (PCD) CT scans by developing a prior knowledge-aware iterative denoising neural network (PKAID-Net) that efficiently exploits the unique noise characteristics of VMIs at different energy (keV) levels. Approach: PKAID-Net offers two major features: first, it utilizes a lower-noise VMI (e.g., 70 keV) as a prior input; second, it iteratively constructs a refined training dataset to improve the neural network's denoising performance. In each iteration, the denoised image from the previous module serves as an updated target image, which is included in the dataset for the subsequent training iteration. Our study includes 10 patient coronary CT angiography exams acquired on a clinical dual-source PCD-CT (NAEOTOM Alpha, Siemens Healthineers). The HR VMIs were reconstructed at 50, 70, and 100 keV, using a sharp vascular kernel (Bv68) and thin (0.6 mm) slice thickness (0.3 mm increment). PKAID-Net's performance was evaluated in terms of image noise, spatial detail preservation, and quantitative accuracy. Results: PKAID-Net achieved a noise reduction of 96% compared to filtered back projection and 65% relative to iterative reconstruction, all while preserving spatial and spectral fidelity and maintaining a natural noise texture. The iterative refinement of PCD-CT data during the training process substantially enhanced the robustness of deep learning-based denoising compared to the original method, which resulted in some spatial detail loss. Conclusions: The PKAID-Net provides substantial noise reduction while maintaining spatial and spectral fidelity of the HR VMIs from PCD-CT.

Indexed as

coronary computed tomography angiographydeep learninghigh resolutionnoise reductionphoton-counting detector CTprior information

Identifiers

PMID38799270
PMCPMC11124219

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.