Evidence map›Paper›PMID 38796111›Full record

ArticleSLAS discovery : advancing life sciences R & D2024

A novel thin plate spline methodology to model tissue surfaces and quantify tumor cell invasion in organ-on-chip models.

Elizabeth Elton, Carly Strelez, Nolan Ung, Rachel Perez, Kimya Ghaffarian, Danielle Hixon, Naim Matasci, Shannon M Mumenthaler

Abstract read
In one paragraph

Article in SLAS discovery : advancing life sciences R & D, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

8 authors.

Elizabeth EltonEllison Institute of Technology, Los Angeles, CA, USA.
Carly StrelezEllison Institute of Technology, Los Angeles, CA, USA.
Nolan UngEllison Institute of Technology, Los Angeles, CA, USA.
Rachel PerezEllison Institute of Technology, Los Angeles, CA, USA.
Kimya GhaffarianEllison Institute of Technology, Los Angeles, CA, USA.
Danielle HixonEllison Institute of Technology, Los Angeles, CA, USA.
Naim MatasciEllison Institute of Technology, Los Angeles, CA, USA.
Shannon M MumenthalerDepartment of Biomedical Engineering, Viterbi School of Engineering, University of Southern California, Los Angeles, CA, USA; Department of Medicine, Norris Comprehensive Cancer Center, Keck School of Medicine, University of Southern California, Los Angeles, CA, USA; Ellison Institute of Technology, Los Angeles, CA, USA. Electronic address: smumenthaler@eit.org.

Funding

A microengineered colon cancer-chip designed to investigate tumor-stromal interactions driving cancer progressionR01CA241137 · NCI · UNIVERSITY OF SOUTHERN CALIFORNIA · PI MUMENTHALER, SHANNON MICHELLE · 2021 to 2025
$2.3M
NCI NIH HHS R01 CA241137
6 · The paper itself

Abstract

Organ-on-chip (OOC) models can be useful tools for cancer drug discovery. Advances in OOC technology have led to the development of more complex assays, yet analysis of these systems does not always account for these advancements, resulting in technical challenges. A challenging task in the analysis of these two-channel microfluidic models is to define the boundary between the channels so objects moving within and between channels can be quantified. We propose a novel imaging-based application of a thin plate spline method - a generalized cubic spline that can be used to model coordinate transformations - to model a tissue boundary and define compartments for quantification of invaded objects, representing the early steps in cancer metastasis. To evaluate its performance, we applied our analytical approach to an adapted OOC developed by Emulate, Inc., utilizing a two-channel system with endothelial cells in the bottom channel and colorectal cancer (CRC) patient-derived organoids (PDOs) in the top channel. Initial application and visualization of this method revealed boundary variations due to microscope stage tilt and ridge and valley-like contours in the endothelial tissue surface. The method was functionalized into a reproducible analytical process and web tool - the Chip Invasion and Contour Analysis (ChICA) - to model the endothelial surface and quantify invading tumor cells across multiple chips. To illustrate applicability of the analytical method, we applied the tool to CRC organoid-chips seeded with two different endothelial cell types and measured distinct variations in endothelial surfaces and tumor cell invasion dynamics. Since ChICA utilizes only positional data output from imaging software, the method is applicable to and agnostic of the imaging tool and image analysis system used. The novel thin plate spline method developed in ChICA can account for variation introduced in OOC manufacturing or during the experimental workflow, can quickly and accurately measure tumor cell invasion, and can be used to explore biological mechanisms in drug discovery.

Indexed as

Lab-On-A-Chip DevicesNeoplasm InvasivenessColorectal NeoplasmsEndothelial CellsHumansMicrofluidicsOrganoidsAutomated analysisCancerImagingInvasionOrgans-on-chipsTopographical methodology

Identifiers

PMID38796111
PMCPMC11199902

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.