Evidence map›Paper›PMID 38794053›Full record

ArticleSensors (Basel, Switzerland)2024

Direct Measurement of Dissolved Gas Using a Tapered Single-Mode Silica Fiber.

Panpan Sun, Mengpeng Hu, Licai Zhu, Hui Zhang, Jinguang Lv, Yu Liu, Jingqiu Liang, Qiang Wang

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Panpan SunKey Laboratory of Advanced Manufacturing for Optical Systems (CAS), Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China.
Mengpeng HuKey Laboratory of Advanced Manufacturing for Optical Systems (CAS), Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China.
Licai ZhuUniversity of Chinese Academy of Sciences, Beijing 100049, China.
Hui ZhangKey Laboratory of Advanced Manufacturing for Optical Systems (CAS), Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China.
Jinguang LvKey Laboratory of Advanced Manufacturing for Optical Systems (CAS), Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China.ORCID 0009-0007-2474-2235
Yu LiuKey Laboratory of Advanced Manufacturing for Optical Systems (CAS), Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China.
Jingqiu LiangKey Laboratory of Advanced Manufacturing for Optical Systems (CAS), Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China.
Qiang WangKey Laboratory of Advanced Manufacturing for Optical Systems (CAS), Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China.ORCID 0000-0001-9875-7500

Funding

Jilin Provincial Natural Science Foundation SKL202302022National Key Research and Development Program of China 2023YFF0714700National Natural Science Foundation of China 62375262the Second Comprehensive Scientific Investigation of the Qinghai-Tibet Plateau 2019QZKK020802the Young Talent of Lifting Engineering for Science and Technology in Jilin, China QT202106
6 · The paper itself

Abstract

Dissolved gases in the aquatic environment are critical to understanding the population of aquatic organisms and the ocean. Currently, laser absorption techniques based on membrane separation technology have made great strides in dissolved gas detection. However, the prolonged water-gas separation time of permeable membranes remains a key obstacle to the efficiency of dissolved gas analysis. To mitigate these limitations, we demonstrated direct measurement of dissolved gas using the evanescent-wave absorption spectroscopy of a tapered silica micro-fiber. It enhanced the analysis efficiency of dissolved gases without water-gas separation or sample preparation. The feasibility of this sensor for direct measurement of dissolved gases was verified by taking the detection of dissolved ammonia as an example. With a sensing length of 5 mm and a consumption of ~50 µL, this sensor achieves a system response time of ~11 min and a minimum detection limit (MDL) of 0.015%. Possible strategies are discussed for further performance improvement in in-situ applications requiring fast and highly sensitive dissolved gas sensing.

Indexed as

direct absorption spectroscopydissolved gasevanescent wavein-situ detectiontapered single-mode silica fiber

Identifiers

PMID38794053
PMCPMC11125180

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.