Design and Characterisation of a Read-Out System for Wireless Monitoring of a Novel Implantable Sensor for Abdominal Aortic Aneurysm Monitoring.

Nuno P Silva, Adnan Elahi, Eoghan Dunne, Martin O'Halloran, Bilal Amin

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Nuno P SilvaTranslational Medical Device Lab, University of Galway, H91 TK33 Galway, Ireland.ORCID 0000-0003-0015-8951
Adnan ElahiTranslational Medical Device Lab, University of Galway, H91 TK33 Galway, Ireland.ORCID 0000-0003-0988-5776
Eoghan DunneTranslational Medical Device Lab, University of Galway, H91 TK33 Galway, Ireland.ORCID 0000-0003-0017-6594
Martin O'HalloranTranslational Medical Device Lab, University of Galway, H91 TK33 Galway, Ireland.ORCID 0000-0002-1650-2940
Bilal AminTranslational Medical Device Lab, University of Galway, H91 TK33 Galway, Ireland.ORCID 0000-0002-4340-1387

Funding

Science Foundation Ireland 18/US-C2C/3447
6 · The paper itself

Abstract

Abdominal aortic aneurysm (AAA) is a dilation of the aorta artery larger than its normal diameter (>3 cm). Endovascular aneurysm repair (EVAR) is a minimally invasive treatment option that involves the placement of a graft in the aneurysmal portion of the aorta artery. This treatment requires multiple follow-ups with medical imaging, which is expensive, time-consuming, and resource-demanding for healthcare systems. An alternative solution is the use of wireless implantable sensors (WIMSs) to monitor the growth of the aneurysm. A WIMS capable of monitoring aneurysm size longitudinally could serve as an alternative monitoring approach for post-EVAR patients. This study has developed and characterised a three-coil inductive read-out system to detect variations in the resonance frequency of the novel Z-shaped WIMS implanted within the AAA sac. Specifically, the spacing between the transmitter and the repeater inductors was optimised to maximise the detection of the sensor by the transmitter inductor. Moreover, an experimental evaluation was also performed for different orientations of the transmitter coil with reference to the WIMS. Finally, the FDA-approved material nitinol was used to develop the WIMS, the transmitter, and repeater inductors as a proof of concept for further studies. The findings of the characterisation from the air medium suggest that the read-out system can detect the WIMS up to 5 cm, regardless of the orientation of the Z-shape WIMS, with the detection range increasing as the orientation approaches 0°. This study provides sufficient evidence that the proposed WIMS and the read-out system can be used for AAA expansion over time.

Indexed as

Aortic Aneurysm, AbdominalWireless TechnologyEquipment DesignHumansMonitoring, PhysiologicProstheses and Implantsabdominal aortic aneurysmEVAR surveillancemagnetic inductive couplingwireless implantable medical sensorZ-shaped inductor

Identifiers

PMID38794049
PMCPMC11126120

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390