Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
2 · The registry
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
5 · Who and what money
Authors and funding
12 authors.
José Luis Cano-PerezFacultad de Medicina y Cirugia, Universidad Autónoma "Benito Juárez" de Oaxaca (FMyC-UABJO), Ex Hacienda de Aguilera S/N, Calz. San Felipe del Agua, Oaxaca de Juárez C.P. 68120, Mexico.ORCID 0000-0002-9213-553X
Jaime Gutiérrez-GutiérrezFacultad de Sistemas Biologicos e Innovacion Tecnologica, Universidad Autónoma "Benito Juárez" de Oaxaca (FASBIT-UABJO), Av. Universidad S/N, Ex-Hacienda 5 Señores, Oaxaca de Juárez C.P. 68120, Mexico.
Christian Perezcampos-MayoralFacultad de Medicina y Cirugia, Universidad Autónoma "Benito Juárez" de Oaxaca (FMyC-UABJO), Ex Hacienda de Aguilera S/N, Calz. San Felipe del Agua, Oaxaca de Juárez C.P. 68120, Mexico.ORCID 0000-0001-8910-5332
Eduardo L Pérez-CamposNational Technology of Mexico/IT Oaxaca, Oaxaca de Juárez C.P. 68033, Mexico.ORCID 0000-0001-6720-7952
María Del Socorro Pina-CansecoFacultad de Medicina y Cirugia, Universidad Autónoma "Benito Juárez" de Oaxaca (FMyC-UABJO), Ex Hacienda de Aguilera S/N, Calz. San Felipe del Agua, Oaxaca de Juárez C.P. 68120, Mexico.ORCID 0000-0002-9486-5093
Lorenzo Tepech-CarrilloFacultad de Sistemas Biologicos e Innovacion Tecnologica, Universidad Autónoma "Benito Juárez" de Oaxaca (FASBIT-UABJO), Av. Universidad S/N, Ex-Hacienda 5 Señores, Oaxaca de Juárez C.P. 68120, Mexico.ORCID 0000-0002-0684-3098
Marciano Vargas-TreviñoFacultad de Sistemas Biologicos e Innovacion Tecnologica, Universidad Autónoma "Benito Juárez" de Oaxaca (FASBIT-UABJO), Av. Universidad S/N, Ex-Hacienda 5 Señores, Oaxaca de Juárez C.P. 68120, Mexico.ORCID 0000-0002-2090-9727
Erick Israel Guerra-HernándezFacultad de Sistemas Biologicos e Innovacion Tecnologica, Universidad Autónoma "Benito Juárez" de Oaxaca (FASBIT-UABJO), Av. Universidad S/N, Ex-Hacienda 5 Señores, Oaxaca de Juárez C.P. 68120, Mexico.
Abraham Martínez-HelmesFacultad de Contaduría y Administración, Universidad Autónoma "Benito Juárez" de Oaxaca (FCA-UABJO), Av. Universidad S/N, Ex-Hacienda 5 Señores, Oaxaca de Juárez C.P. 68120, Mexico.
Julián Moisés Estudillo-AyalaDivision de Ingenierias, Campus Irapuato-Salamanca, Universidad de Guanajuato, Carretera Salamanca-Valle de Santiago km 3.5 + 1.8, Comunidad de Palo Blanco, Salamanca C.P. 36885, Mexico.ORCID 0000-0002-4010-3800
Juan Manuel Sierra-HernándezDivision de Ingenierias, Campus Irapuato-Salamanca, Universidad de Guanajuato, Carretera Salamanca-Valle de Santiago km 3.5 + 1.8, Comunidad de Palo Blanco, Salamanca C.P. 36885, Mexico.
Roberto Rojas-LagunaDivision de Ingenierias, Campus Irapuato-Salamanca, Universidad de Guanajuato, Carretera Salamanca-Valle de Santiago km 3.5 + 1.8, Comunidad de Palo Blanco, Salamanca C.P. 36885, Mexico.
Funding
No grant is acknowledged in the PubMed record.
6 · The paper itself
Abstract
In this work, we experimentally analyzed and demonstrated the performance of an in-line Mach-Zehnder interferometer in the visible region, with an LED light source. The different waist diameter taper and asymmetric core-offset interferometers proposed used a single-mode fiber (SMF). The visibility achieved was V = 0.14 with an FSR of 23 nm for the taper MZI structure and visibilities of V = 0.3, V = 0.27, and V = 0.34 with FSRs of 23 nm, 17 nm, and 8 nm and separation lengths L of 2.5 cm, 4.0 cm, and 5.0 cm between the core-offset structure, respectively. The experimental investigation of the response to the temperature sensor yielded values from 50 °C to 300 °C; the sensitivity obtained was 3.53 a.u./°C, with R2 of 0.99769 and 1% every 1 °C in the transmission. For a range of 50 °C to 150 °C, 20.3 pm/°C with a R2 of 0.96604 was obtained.
Indexed as
bi-tapers and core-offset Mach–Zehnder interferometertemperature sensorwhite light interference
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.
Experimental Study of White Light Interferometry in Mach-Zehnder Interferometers Based on Standard Single Mode Fiber. · full record | OpenQuestion