ReviewJournal of clinical medicine2024
Advances in Dynamization of Plate Fixation to Promote Natural Bone Healing.
Review in Journal of clinical medicine, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
11 citing papers in PubMed, 1 synthesis or guideline pooled it.
- Dynamic Fracture Fixation Plates: A Systematic Review of Evolving Design Approaches.Annals of biomedical engineering · 2025Pooled it
- Staged screw removal in external plate fixation for distal tibial fractures: a finite element study on adaptive biomechanics.Scientific reports · 2026Article
- Bone Formation Between 2.5 and 25% Interfragmentary Strain Induced by Immediate and Delayed Loading in a Bone Healing Model with a Monotonic Strain Gradient.Annals of biomedical engineering · 2026Article
- Bicolumnar Stabilization of Bicondylar Tibial Plateau Injuries: A Prospective Study of Combined Buttress Plate and Titanium Elastic Nail Fixation.Journal of orthopaedic case reports · 2026Article
- Mechano-immune interactions in musculoskeletal aging: Mechanisms and translational perspectives.Theranostics · 2026Review
- Revisiting bone healing strategies: the potential of reverse dynamization in veterinary orthopedics.Frontiers in veterinary science · 2026Review
- Engagement and Stress Concentration Evaluation of a Novel Two-Part Compression Screw: A Preliminary Finite Element Analysis.Bioengineering (Basel, Switzerland) · 2025Article
- Modification of a Two-Part Cancellous Locking Screw: A Pilot Study on Increasing Resistance to Axial Pullout Strength.Bioengineering (Basel, Switzerland) · 2025Article
- A novel external fixation for treating tibial fractures: a finite element and biomechanical study.Journal of orthopaedic surgery and research · 2025Article
- Spinal surgery in the context of end-stage renal disease: Balancing risks and surgical strategies - A narrative review.Tzu chi medical journalReview
- Strain-Dependent Effects of Controlled Micromotion on Fracture Healing: Rethinking the Strain Threshold.JB & JS open accessArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
Abstract
The controlled dynamization of fractures can promote natural fracture healing by callus formation, while overly rigid fixation can suppress healing. The advent of locked plating technology enabled new strategies for the controlled dynamization of fractures, such as far cortical locking (FCL) screws or active plates with elastically suspended screw holes. However, these strategies did not allow for the use of non-locking screws, which are typically used to reduce bone fragments to the plate. This study documents the first in vivo study on the healing of ovine tibia osteotomies stabilized with an advanced active plate (AAP). This AAP allowed plate application using any combination of locking and non-locking screws to support a wide range of plate application techniques. At week 9 post-surgery, tibiae were harvested and tested in torsion to failure to assess the healing strength. The five tibiae stabilized with an AAP regained 54% of their native strength and failed by spiral fracture through a screw hole, which did not involve the healed osteotomy. In comparison, tibiae stabilized with a standard locking plate recovered 17% of their strength and sustained failure through the osteotomy. These results further support the stimulatory effect of controlled motion on fracture healing. As such, the controlled dynamization of locked plating constructs may hold the potential to reduce healing complications and may shorten the time to return to function. Integrating controlled dynamization into fracture plates that support a standard fixation technique may facilitate the clinical adoption of dynamic plating.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.