Evidence map›Paper›PMID 38790312›Full record

ArticleBioengineering (Basel, Switzerland)2024

An Automated Video Analysis System for Retrospective Assessment and Real-Time Monitoring of Endoscopic Procedures (with Video).

Yan Zhu, Ling Du, Pei-Yao Fu, Zi-Han Geng, Dan-Feng Zhang, Wei-Feng Chen, Quan-Lin Li, Ping-Hong Zhou

Abstract read
In one paragraph

Article in Bioengineering (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Yan ZhuEndoscopy Center and Endoscopy Research Institute, Zhongshan Hospital, Fudan University, Shanghai 200032, China.
Ling DuEndoscopy Center and Endoscopy Research Institute, Zhongshan Hospital, Fudan University, Shanghai 200032, China.
Pei-Yao FuEndoscopy Center and Endoscopy Research Institute, Zhongshan Hospital, Fudan University, Shanghai 200032, China.
Zi-Han GengEndoscopy Center and Endoscopy Research Institute, Zhongshan Hospital, Fudan University, Shanghai 200032, China.
Dan-Feng ZhangEndoscopy Center and Endoscopy Research Institute, Zhongshan Hospital, Fudan University, Shanghai 200032, China.
Wei-Feng ChenEndoscopy Center and Endoscopy Research Institute, Zhongshan Hospital, Fudan University, Shanghai 200032, China.
Quan-Lin LiEndoscopy Center and Endoscopy Research Institute, Zhongshan Hospital, Fudan University, Shanghai 200032, China.
Ping-Hong ZhouEndoscopy Center and Endoscopy Research Institute, Zhongshan Hospital, Fudan University, Shanghai 200032, China.ORCID 0000-0002-5434-0540

Funding

Major Project of Shanghai Municipal Science and Technology Committee 19441905200National Key R&D Program of China 2019YFC1315800National Natural Science Foundation of China 81670483National Natural Science Foundation of China 81873552National Natural Science Foundation of China 82170555Shanghai Rising-Star Program 19QA1401900Shanghai Sailing Programs of Shanghai Municipal Science and Technology Committee 19YF1406400Shanghai Sailing Programs of Shanghai Municipal Science and Technology Committee 22YF1409300
6 · The paper itself

Abstract

BACKGROUND AND

aimsAccurate recognition of endoscopic instruments facilitates quantitative evaluation and quality control of endoscopic procedures. However, no relevant research has been reported. In this study, we aimed to develop a computer-assisted system, EndoAdd, for automated endoscopic surgical video analysis based on our dataset of endoscopic instrument images.

methodsLarge training and validation datasets containing 45,143 images of 10 different endoscopic instruments and a test dataset of 18,375 images collected from several medical centers were used in this research. Annotated image frames were used to train the state-of-the-art object detection model, YOLO-v5, to identify the instruments. Based on the frame-level prediction results, we further developed a hidden Markov model to perform video analysis and generate heatmaps to summarize the videos.

resultsEndoAdd achieved high accuracy (>97%) on the test dataset for all 10 endoscopic instrument types. The mean average accuracy, precision, recall, and F1-score were 99.1%, 92.0%, 88.8%, and 89.3%, respectively. The area under the curve values exceeded 0.94 for all instrument types. Heatmaps of endoscopic procedures were generated for both retrospective and real-time analyses.

conclusionsWe successfully developed an automated endoscopic video analysis system, EndoAdd, which supports retrospective assessment and real-time monitoring. It can be used for data analysis and quality control of endoscopic procedures in clinical practice.

Indexed as

artificial intelligenceendoscopic resectionreal-time video analysissurgical video

Identifiers

PMID38790312
PMCPMC11118061

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.